INTENSITAS PENCAHAYAAN ALAMI PADA RUANG PERTEMUAN DI GEDUNG COT, FAKULTAS TEKNIK GOWA, UNIVERSITAS HASANUDDIN

Annajma Nurul Wika, Nurul Jamala
{"title":"INTENSITAS PENCAHAYAAN ALAMI PADA RUANG PERTEMUAN DI GEDUNG COT, FAKULTAS TEKNIK GOWA, UNIVERSITAS HASANUDDIN","authors":"Annajma Nurul Wika, Nurul Jamala","doi":"10.21460/ATRIUM.V5I1.73","DOIUrl":null,"url":null,"abstract":"\n \n \nTitle: Natural Light Intensity Analysis in the Meeting Room at COT Building, Gowa Engineering Faculty, Hasanuddin University \nLighting is an essential factor in supporting out activities. However, excessive brightness can also cause discomfort. This study aims to examine the intensity of natural lighting in the meeting room of the COT building, Faculty of Engineering, Hasanuddin University. This type of research used is quantitative analysis and data collection methods directly using the lux meter measuring instrument, then presented in tabular form. The study's conclusion is that the intensity of natural lighting in the meeting room of the 1st floor, 2nd and 3rd-floor COT buildings, all exceeding 300 lux from the lighting standards. The average significant light intensity outside the building with clear sky conditions in the morning is 29950 lux; daytime is 18360 lux and afternoon is 14550 lux. The average light intensity outside the building with cloudy sky conditions in the morning is 9200 lux, daytime is 8750 lux, and afternoon is 9350 lux. The average significant light intensity outside the building with cloudy sky conditions in the morning is 3250 lux, daytime is 6610 lux, and the afternoon is 5425 lux. The magnitude of the natural light intensity outside the building with any sky conditions significantly affects the natural lighting in the building. The higher the intensity of the sun light outside the building, the higher the illumination that comes to the building. \n \n \n","PeriodicalId":306403,"journal":{"name":"ATRIUM: Jurnal Arsitektur","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ATRIUM: Jurnal Arsitektur","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21460/ATRIUM.V5I1.73","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Title: Natural Light Intensity Analysis in the Meeting Room at COT Building, Gowa Engineering Faculty, Hasanuddin University Lighting is an essential factor in supporting out activities. However, excessive brightness can also cause discomfort. This study aims to examine the intensity of natural lighting in the meeting room of the COT building, Faculty of Engineering, Hasanuddin University. This type of research used is quantitative analysis and data collection methods directly using the lux meter measuring instrument, then presented in tabular form. The study's conclusion is that the intensity of natural lighting in the meeting room of the 1st floor, 2nd and 3rd-floor COT buildings, all exceeding 300 lux from the lighting standards. The average significant light intensity outside the building with clear sky conditions in the morning is 29950 lux; daytime is 18360 lux and afternoon is 14550 lux. The average light intensity outside the building with cloudy sky conditions in the morning is 9200 lux, daytime is 8750 lux, and afternoon is 9350 lux. The average significant light intensity outside the building with cloudy sky conditions in the morning is 3250 lux, daytime is 6610 lux, and the afternoon is 5425 lux. The magnitude of the natural light intensity outside the building with any sky conditions significantly affects the natural lighting in the building. The higher the intensity of the sun light outside the building, the higher the illumination that comes to the building.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
哈萨鲁丁大学GOWA工程系科特大厅的自然照明强度
题目:Hasanuddin大学Gowa工程学院COT大楼会议室的自然光强度分析照明是支持我们活动的重要因素。然而,过度的亮度也会引起不适。本研究旨在研究哈萨努丁大学工程学院COT大楼会议室的自然采光强度。这类研究采用的是直接利用勒克斯计测量仪器进行定量分析和数据收集的方法,然后以表格的形式呈现出来。研究的结论是,1层、2层和3层COT建筑的会议室的自然光强度均超过了300勒克斯的照明标准。清晨晴空条件下,建筑外平均显著光强为29950勒克斯;白天是18360勒克斯,下午是14550勒克斯。阴天条件下,上午平均光照强度为9200勒克斯,白天为8750勒克斯,下午为9350勒克斯。阴天条件下,上午建筑外平均显著光强为3250勒克斯,白天为6610勒克斯,下午为5425勒克斯。在任何天空条件下,建筑外的自然光强度的大小都会显著影响建筑内的自然采光。建筑外的太阳光强度越高,进入建筑的照度就越高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Elemen Pembentuk Sense of Place Taman Nostalgia sebagai Ruang Terbuka Publik Kota Kupang Kebertahanan Bangunan dengan Adaptif terhadap Lingkungan Analisis Penerapan Konsep Desain Arsitektur Tropis pada Hotel Alila Seminyak, Bali Resiliensi Kawasan Permukiman Desa Pacarejo, Semanu, Kabupaten Gunung Kidul Terhadap Bencana Alam Puting Beliung Akulturasi dalam Arsitektur Jawa di Yogyakarta
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1