Direct torque control of permanent magnet synchronous motor drive with a sensorless initial rotor position estimation scheme

S. Kar, S. Mishra
{"title":"Direct torque control of permanent magnet synchronous motor drive with a sensorless initial rotor position estimation scheme","authors":"S. Kar, S. Mishra","doi":"10.1109/APCET.2012.6301999","DOIUrl":null,"url":null,"abstract":"Direct torque control (DTC) can be applied to all AC machine drives. The synchronous motor torque control, based on DTC structure, permits to obtain high dynamic performances. DTC is a concrete solution to robustness and dynamic problems found in other control structures. In DTC scheme, the requirement of the continuous rotor position sensor and co-ordinate transformation is eliminated since all the calculation is done in stator reference frame. However; the DTC scheme requires the position sensor to determine the initial position of rotor at starting. Elimination of the shaft mounted position encoder is a very desirable objective in many applications as this sensor is often one of the most fragile components in the entire drive system. This paper presents the implementation of DTC to Permanent magnet synchronous motor (PMSM) with a sensorless initial rotor position estimation scheme. The requirement of sensor for the initial rotor position estimation can be avoided by impressing a high frequency voltage on the stator winding. The simulation results verify the effectiveness of the process.","PeriodicalId":184844,"journal":{"name":"2012 International Conference on Advances in Power Conversion and Energy Technologies (APCET)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Advances in Power Conversion and Energy Technologies (APCET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APCET.2012.6301999","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Direct torque control (DTC) can be applied to all AC machine drives. The synchronous motor torque control, based on DTC structure, permits to obtain high dynamic performances. DTC is a concrete solution to robustness and dynamic problems found in other control structures. In DTC scheme, the requirement of the continuous rotor position sensor and co-ordinate transformation is eliminated since all the calculation is done in stator reference frame. However; the DTC scheme requires the position sensor to determine the initial position of rotor at starting. Elimination of the shaft mounted position encoder is a very desirable objective in many applications as this sensor is often one of the most fragile components in the entire drive system. This paper presents the implementation of DTC to Permanent magnet synchronous motor (PMSM) with a sensorless initial rotor position estimation scheme. The requirement of sensor for the initial rotor position estimation can be avoided by impressing a high frequency voltage on the stator winding. The simulation results verify the effectiveness of the process.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
永磁同步电机驱动直接转矩控制的无传感器初始转子位置估计方案
直接转矩控制(DTC)可以应用于所有交流机器驱动器。同步电机转矩控制采用直接转矩控制结构,具有较高的动态性能。直接转矩控制是解决其它控制结构鲁棒性和动态性问题的具体方法。在直接转矩控制方案中,所有的计算都在定子参照系中完成,从而消除了转子位置连续传感器和坐标变换的要求。然而;DTC方案要求位置传感器在启动时确定转子的初始位置。在许多应用中,消除轴安装位置编码器是一个非常理想的目标,因为这种传感器通常是整个驱动系统中最脆弱的部件之一。提出了一种无传感器转子初始位置估计方案,实现了永磁同步电机的直接转矩控制。通过在定子绕组上施加高频电压,可以避免传感器对转子初始位置估计的要求。仿真结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An effective approach for ATC enhancement with FACTS device - A case study Hybrid controller for inverted pendulum Congestion management in a pool model with bilateral contract by generation rescheduling based on PSO A novel linear controller for grid connected doubly fed induction generator (DFIG) Interval type-2 fuzzy logic controller as a power system stabilizer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1