{"title":"The hilbert transform adaptation for measuring amplitude and phase low-frequency disturbances in power system voltage","authors":"A. Bień","doi":"10.1109/ISNCC.2008.4627506","DOIUrl":null,"url":null,"abstract":"Phase disturbances in electric power signals are neglected and only amplitude (envelope) distortions are discussed in a literature. Amplitude disturbances are interpreted as amplitude modulation (AM) of main 50 Hz frequency. Detailed analysis of all disturbances and their sources are presented in the paper. It is shown that AM and narrow band PM (phase modulation) take place in power network simultaneously and those two modulations interact with each other. Voltage variation is proposed as disturbances measurement. Theoretical results are verified by field experiments and their results are presented.","PeriodicalId":143815,"journal":{"name":"2008 International School on Nonsinusoidal Currents and Compensation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International School on Nonsinusoidal Currents and Compensation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNCC.2008.4627506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Phase disturbances in electric power signals are neglected and only amplitude (envelope) distortions are discussed in a literature. Amplitude disturbances are interpreted as amplitude modulation (AM) of main 50 Hz frequency. Detailed analysis of all disturbances and their sources are presented in the paper. It is shown that AM and narrow band PM (phase modulation) take place in power network simultaneously and those two modulations interact with each other. Voltage variation is proposed as disturbances measurement. Theoretical results are verified by field experiments and their results are presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
希尔伯特变换自适应测量电力系统电压的幅相低频扰动
电力信号中的相位干扰被忽略,文献中只讨论幅度(包络)畸变。振幅干扰被解释为主50hz频率的振幅调制(AM)。文中详细分析了各种干扰及其来源。结果表明,调幅调制和窄带调相调制在电网中同时发生,并相互作用。电压变化被提出作为扰动测量。通过现场试验对理论结果进行了验证,并给出了实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Instantaneous single-phase system power demonstration using virtual two phase theory Power quality conditioners with minimum number of current sensor requirement Power electronics active filter with controlled dynamics Conditions of CM voltage cancellation in multilevel voltage inverters with conventional and improved carrier-based SVPWM Natural doubling of the apparent switching frequency using three-level ANPC converter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1