Research on the Protection Range of Distance Protection Zone I for Short Transmission Line

Zhao Zhihong, Zhao Yue, Cheng Lei, Wang Bin, Huang Zhihua
{"title":"Research on the Protection Range of Distance Protection Zone I for Short Transmission Line","authors":"Zhao Zhihong, Zhao Yue, Cheng Lei, Wang Bin, Huang Zhihua","doi":"10.1109/ciced.2018.8592250","DOIUrl":null,"url":null,"abstract":"This thesis mainly analyzes the applications of distance protection zone I for short transmission line or weak-infeed. It demonstrates the calculation method of shortest length of transmission line that distance protection zone I can be applied at power source side and gives suggestions of setting calculation. Moreover, it analyzes the large error between measured impedance value and actual fault impedance, because distance protection zone I may work improperly when distance protection used for weak-infeed side.","PeriodicalId":142885,"journal":{"name":"2018 China International Conference on Electricity Distribution (CICED)","volume":"147 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ciced.2018.8592250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This thesis mainly analyzes the applications of distance protection zone I for short transmission line or weak-infeed. It demonstrates the calculation method of shortest length of transmission line that distance protection zone I can be applied at power source side and gives suggestions of setting calculation. Moreover, it analyzes the large error between measured impedance value and actual fault impedance, because distance protection zone I may work improperly when distance protection used for weak-infeed side.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
短线距离保护I区保护范围的研究
本文主要分析了距离保护I在短线或弱馈电中的应用。论证了电源侧可采用距离保护区I的输电线路最短长度的计算方法,并给出了整定计算建议。分析了在弱馈电侧采用距离保护时,距离保护I区可能工作不正常,导致测量阻抗值与实际故障阻抗误差较大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Deep Game Bidding Model and Practice of Electricity Market Research on Fault Location for UHV Half-wavelength Transmission Lines Comprehensive Evaluation of Insulation Performance of DC XLPE Cables Improvement of Distribution System Maintenance Plan Based on Risk Level The Application of Transient Calculation for Loop Closing of Distribution Network Based on The DSA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1