Results of an Instrumented Static Loading Test and Its Application to Design Compilation of an International Survey

B. Fellenius
{"title":"Results of an Instrumented Static Loading Test and Its Application to Design Compilation of an International Survey","authors":"B. Fellenius","doi":"10.37308/DFIJNL.20200923.224","DOIUrl":null,"url":null,"abstract":"Results of a static loading test were used together with soil exploration records in a survey comprising analysis of the test records and estimating settlement of piled foundation to support a pipe rack. The test pile was a strain-gage instrumented, 400-mm diameter, precast, prestressed concrete pile driven into a clay and silt deposit to 25 m embedment. Two main issues were expected to be addressed by the survey participants: First, realization that the strain records were affected by presence of residual force in the pile and, second, calculation of the settlement of the piled foundation expected from the foundation load. A total of 52 submissions were received from 20 different countries. Only 12 of the submissions realized the presence of residual force. Most submissions reported a calculated settlement of the piled foundations ranging from 10 mm through 50 mm; however, 11 reported values between 60 and 200 mm. Surprisingly, only 20 submissions reported ground surface settlement close to the 200-mm value resulting from textbook analysis based on the available information. The subsequent construction of the piled foundations coincided with placing a fill across the site and lowering of the groundwater table, thus, causing a general subsidence.","PeriodicalId":339795,"journal":{"name":"DFI Journal: The Journal of the Deep Foundations Institute","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DFI Journal: The Journal of the Deep Foundations Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37308/DFIJNL.20200923.224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Results of a static loading test were used together with soil exploration records in a survey comprising analysis of the test records and estimating settlement of piled foundation to support a pipe rack. The test pile was a strain-gage instrumented, 400-mm diameter, precast, prestressed concrete pile driven into a clay and silt deposit to 25 m embedment. Two main issues were expected to be addressed by the survey participants: First, realization that the strain records were affected by presence of residual force in the pile and, second, calculation of the settlement of the piled foundation expected from the foundation load. A total of 52 submissions were received from 20 different countries. Only 12 of the submissions realized the presence of residual force. Most submissions reported a calculated settlement of the piled foundations ranging from 10 mm through 50 mm; however, 11 reported values between 60 and 200 mm. Surprisingly, only 20 submissions reported ground surface settlement close to the 200-mm value resulting from textbook analysis based on the available information. The subsequent construction of the piled foundations coincided with placing a fill across the site and lowering of the groundwater table, thus, causing a general subsidence.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
仪器静载试验结果及其在国际测量设计编制中的应用
静载试验的结果与土壤勘探记录一起用于一项调查,包括对试验记录的分析和对支撑管架的桩基础沉降的估计。试桩采用应变仪,直径400 mm,预制预应力混凝土桩,打入粘土和淤泥沉积物,嵌入25 m。调查参与者希望解决两个主要问题:第一,认识到应变记录受到桩中残余力的影响;第二,计算基础荷载预期的桩基础沉降。共收到来自20个不同国家的52份意见书。只有12份意见书意识到存在残余部队。大多数提交的材料报告了桩基础的计算沉降,范围从10毫米到50毫米;然而,11个报告的值在60到200毫米之间。令人惊讶的是,只有20份提交报告的地表沉降接近200毫米的值,这是根据现有信息根据教科书分析得出的。随后的桩基施工与填充物的放置和地下水位的降低同时进行,因此造成了总体的下沉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results of an Instrumented Static Loading Test and Its Application to Design Compilation of an International Survey Resistance Factors at Serviceability Limit State Using the Texas Cone Penetrometer as the Predictive Model Geotechnical Resistances of Drilled Shafts in Triassic Basin Sedimentary Rocks Skin Friction Directionality in Monotonically- and Cyclically-Loaded Bio-inspired Piles in Sand Full-Scale Load Testing and Extraction of Augered Cast-in-Place (ACIP) Piles in Central Florida
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1