{"title":"Harmonic Intelligent Control with Active Power Filter","authors":"T. El-fetoh","doi":"10.1109/UPEC.2006.367629","DOIUrl":null,"url":null,"abstract":"This paper presents the procedures required to determine the locations and sizes of multiple-active power filters (APFs) to reduce harmonic distortion in a power system with harmonic sources. The objective function is to minimize the APFs injection currents while satisfying harmonic voltages, total harmonic voltage distortions within IEEE-519 recommended limits and the maximum rating current limit of each installed APF. The APFs are located at the points having harmonic sources or higher harmonic distortions, while minimizing injection currents. The ANN Model is developed to determine size and location of APF. A typical 28-bus distribution system is selected to verify the validity of the proposed procedures","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367629","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

This paper presents the procedures required to determine the locations and sizes of multiple-active power filters (APFs) to reduce harmonic distortion in a power system with harmonic sources. The objective function is to minimize the APFs injection currents while satisfying harmonic voltages, total harmonic voltage distortions within IEEE-519 recommended limits and the maximum rating current limit of each installed APF. The APFs are located at the points having harmonic sources or higher harmonic distortions, while minimizing injection currents. The ANN Model is developed to determine size and location of APF. A typical 28-bus distribution system is selected to verify the validity of the proposed procedures
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
有源电力滤波器谐波智能控制
本文介绍了在有谐波源的电力系统中,确定多有源电力滤波器的位置和尺寸以减小谐波畸变所需的程序。目标函数是最小化APF注入电流,同时满足谐波电压、总谐波电压畸变在IEEE-519推荐限值内以及每个安装的APF的最大额定电流限值。apf位于具有谐波源或更高谐波畸变的点上,同时最小化注入电流。建立了人工神经网络模型来确定有源滤波器的大小和位置。选择一个典型的28总线配电系统来验证所提出程序的有效性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient Short-Circuit Behaviour of Distributed Energy Sources and Their Influence on Protection Coordination Using Active Power Filter Based on New Control Strategy to Compensate Power Quality Assessment of DSM Potential in the Governmental Sector in Egypt and its Effect on the National Power System Development A New Method for the Price Determination of the Reactive Power Supply Grid Integration of Wind Farms Using SVC and STATCOM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1