IDENTIFICATION AQUIFER PARAMETERS THROUGH SINGLE WELL PUMPING TEST SERIES AT PT. KALTIM KARIANGAU TERMINAL, BALIKPAPAN, EAST KALIMANTAN

T. Sulistyo
{"title":"IDENTIFICATION AQUIFER PARAMETERS THROUGH SINGLE WELL PUMPING TEST SERIES AT PT. KALTIM KARIANGAU TERMINAL, BALIKPAPAN, EAST KALIMANTAN","authors":"T. Sulistyo","doi":"10.32511/JUTEKS.V3I2.283","DOIUrl":null,"url":null,"abstract":"Aquifer Parameters are very important in groundwater and well management. The objective of this research is to determine aquifer parameter in order to be used in determining suitable production rate of well. Research was carried out in PT. Kaltim Kariangau Terminal, which is administratively, located in Balikpapan City, East Kalimantan, Indonesia. PT. Kaltim Kariangau Terminal has developed four wells with distance of each of well is between 50 and 300 meters, but it is a pity because just one well was completed by pumping test without observation well. Result of constant pumping test analyzing through Cooper – Jacob method has shown that value of Transmissivity (T) of aquifer is 319.0718283 m2/day, and it is known from geophysical logging and well construction design that the thickness of aquifer is 48 m, so hydraulic conductivity (K) of aquifer is 6.6473 m/day. Coefficient of aquifer loss is 0.0013 and coefficient of well loss is 0.0000008. Factors development of well could be classified as very effective with the well condition is properly designed and developed.","PeriodicalId":138866,"journal":{"name":"JUTEKS - Jurnal Teknik Sipil","volume":"98 10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JUTEKS - Jurnal Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32511/JUTEKS.V3I2.283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aquifer Parameters are very important in groundwater and well management. The objective of this research is to determine aquifer parameter in order to be used in determining suitable production rate of well. Research was carried out in PT. Kaltim Kariangau Terminal, which is administratively, located in Balikpapan City, East Kalimantan, Indonesia. PT. Kaltim Kariangau Terminal has developed four wells with distance of each of well is between 50 and 300 meters, but it is a pity because just one well was completed by pumping test without observation well. Result of constant pumping test analyzing through Cooper – Jacob method has shown that value of Transmissivity (T) of aquifer is 319.0718283 m2/day, and it is known from geophysical logging and well construction design that the thickness of aquifer is 48 m, so hydraulic conductivity (K) of aquifer is 6.6473 m/day. Coefficient of aquifer loss is 0.0013 and coefficient of well loss is 0.0000008. Factors development of well could be classified as very effective with the well condition is properly designed and developed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
东加里曼丹balikpapan kaltim kariangau码头单井抽水试验系列识别含水层参数
含水层参数在地下水和井的管理中是非常重要的。本文研究的目的是确定含水层参数,以便确定合适的油井产量。研究是在PT. Kaltim Kariangau码头进行的,该码头在行政上位于印度尼西亚东加里曼丹的巴厘巴潘市。PT. Kaltim Kariangau Terminal已经开发了4口井,每口井的井距在50 ~ 300米之间,但遗憾的是,只有一口井是在没有观察井的情况下通过泵送测试完成的。通过Cooper - Jacob法恒抽水试验分析结果表明,含水层透光率(T)值为319.0718283 m2/day,通过地球物理测井和施工设计得知含水层厚度为48 m,则含水层的导水率(K)为6.6473 m/day。含水层损失系数为0.0013,井损系数为0.0000008。只要合理设计和开发井况,井的因素开发是非常有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
STUDI PENANGANAN KERUSAKAN PANTAI DI KAWASAN WISATA PESISIR TELUK KUPANG APLIKASI BUILDING INFORMASI MODELING (BIM) TEKLA STRUCTURE PADA KONSTRUKSI ATAP DOME GEDUNG OLAHRAGA UTP SURAKARTA IDENTIFICATION AQUIFER PARAMETERS THROUGH SINGLE WELL PUMPING TEST SERIES AT PT. KALTIM KARIANGAU TERMINAL, BALIKPAPAN, EAST KALIMANTAN STUDI PARAMETRIK: KINERJA SEISMIK KOLOM KOMPOSIT EWECS (ENGINEERING WOOD ENCASED CONCRETE-STEEL) DENGAN BAJA PROFIL KING CROSS MANAJEMEN LALU LINTAS DI JALAN LINGKAR KAMPUS UNIVERSITAS BRAWIJAYA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1