Selecting the excitation system for the additional turbine generator at the Port Wentworth pulp mill

R. Jordan, R. Schaefer, J.A. Estes, M. R. Dube
{"title":"Selecting the excitation system for the additional turbine generator at the Port Wentworth pulp mill","authors":"R. Jordan, R. Schaefer, J.A. Estes, M. R. Dube","doi":"10.1109/PAPCON.2004.1338370","DOIUrl":null,"url":null,"abstract":"Weyerhaeuser Company owns a market softwood pulp manufacturing facility at Port Wentworth, GA and the company was looking for a way to reduce manufacturing costs. It was determined that if a used steam turbine generator could be installed at the plant, this would be a viable way to reduce manufacturing costs. The unit would displace purchased electrical energy with \"in house\" generation during times that the plant could produce the energy for less than it would be charged by the electric utility. During these times, the unit would be operated in a mode such that the electrical energy flowing into the plant through the utility intertie would be kept to a minimum (tie line control mode). During other times of the year, providing that it was economical, the plant could sell electrical energy to the utility. Once the unit was purchased and the degree of reconditioning and repairs to the turbine and the generator had been determined, the next major decision was which of the auxiliary systems could be re-used. This paper covers the process involved in evaluating whether or not to reuse the generator's original compound excitation system and if replaced, the type of excitation system that should be installed, compound or potential bus fed type. Discussed are the issues encountered during the evaluation process, the expectations desired, the decisions made and the outcome achieved as a result of the final decision to replace the existing compound excitation system with a potential bus fed excitation system.","PeriodicalId":189773,"journal":{"name":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","volume":"6 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2004.1338370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Weyerhaeuser Company owns a market softwood pulp manufacturing facility at Port Wentworth, GA and the company was looking for a way to reduce manufacturing costs. It was determined that if a used steam turbine generator could be installed at the plant, this would be a viable way to reduce manufacturing costs. The unit would displace purchased electrical energy with "in house" generation during times that the plant could produce the energy for less than it would be charged by the electric utility. During these times, the unit would be operated in a mode such that the electrical energy flowing into the plant through the utility intertie would be kept to a minimum (tie line control mode). During other times of the year, providing that it was economical, the plant could sell electrical energy to the utility. Once the unit was purchased and the degree of reconditioning and repairs to the turbine and the generator had been determined, the next major decision was which of the auxiliary systems could be re-used. This paper covers the process involved in evaluating whether or not to reuse the generator's original compound excitation system and if replaced, the type of excitation system that should be installed, compound or potential bus fed type. Discussed are the issues encountered during the evaluation process, the expectations desired, the decisions made and the outcome achieved as a result of the final decision to replace the existing compound excitation system with a potential bus fed excitation system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
为温特沃斯港纸浆厂的附加涡轮发电机选择励磁系统
惠好公司在乔治亚州温特沃斯港拥有一家市场软木纸浆制造工厂,该公司正在寻找一种降低制造成本的方法。经确定,如果可以在工厂安装一台二手蒸汽涡轮发电机,这将是降低制造成本的可行方法。该装置将取代购买的电能与“内部”发电,在时间内,工厂可以产生的能量比它将由电力公用事业充电。在此期间,机组将在这样一种模式下运行,即通过公用事业网络流入工厂的电能将保持在最低限度(线路控制模式)。在一年中的其他时间,如果经济的话,电厂可以把电能卖给公用事业公司。一旦机组被购买,涡轮机和发电机的整修和修理程度已经确定,下一个主要决定是哪些辅助系统可以重新使用。本文介绍了评估是否重新使用发电机原有的复合励磁系统的过程,如果更换,应安装的励磁系统类型是复合励磁还是电位母线馈电励磁。讨论了在评估过程中遇到的问题,期望,所做的决定以及最终决定用潜在的母线馈电励磁系统取代现有的复合励磁系统所取得的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Medium voltage reduced voltage autotransformer starter failures $explaining the unexplained Direct drive induction motors Optimizing NEMA TP 1 transformers for process industry substation service Safety aspects of permanent magnet motors in paper machine applications A unique paper machine drive system revamp
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1