Removal Torque Analyses of Two Self-drilling Orthodontic Temporary Anchorage Devices (TADs)

M. Mohamed
{"title":"Removal Torque Analyses of Two Self-drilling Orthodontic Temporary Anchorage Devices (TADs)","authors":"M. Mohamed","doi":"10.33805/2572-6978.130","DOIUrl":null,"url":null,"abstract":"Stability of miniscrews or Temporary Anchorage Devices (TADs) is an essential factor for successful application in orthodontics. Miniscrews removal torque can be used as an indicator of miniscrews stability. The objective of this work was to compare removal torque between self-drilling tapered mini-screws and cylindrical miniscrews. Materials and Methods: Two groups of TADs were inserted in the maxillae of orthodontic patients to provide stationary anchorage for front teeth retraction. Group 1: 20 tapered self-drilling miniscrews, Group 2: 20 cylindrical self-drilling miniscrew. Split mouth technique was used. All of the TADs were inserted parallel to the occlusal plane, between roots of the 2nd maxillary premolar and 1st maxillary molar. The TADs were immediately loaded with constant and continuous load using 8 mm long heavy short Nickel Titanium coil spring. The coil spring was stretched between the heads of the two types of TADs and crimpable hooks that fixed on arch wire just distal to the anterior six maxillary teeth. After complete retraction of the anterior maxillary teeth, TADs were removed using torque adjustable screw-removal. At the moment of movement of the TAD the torque was recorded in Newton Centimeter (Ncm). Results: Mann Whitney U Test resulted in a significant difference between the two groups, indicating that cylindrical TADs had significantly higher removal torque than tapered TADs (means were 3.20 Ncm ± 0.20 and 2.70 Ncm ± 0.10 respectively). Conclusion: Physical properties have a considerable influence on the stability of the TADs. Cylindrical TADs are showed more mechanical interlock into the bone.","PeriodicalId":165937,"journal":{"name":"Dental Research and Management","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Research and Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33805/2572-6978.130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Stability of miniscrews or Temporary Anchorage Devices (TADs) is an essential factor for successful application in orthodontics. Miniscrews removal torque can be used as an indicator of miniscrews stability. The objective of this work was to compare removal torque between self-drilling tapered mini-screws and cylindrical miniscrews. Materials and Methods: Two groups of TADs were inserted in the maxillae of orthodontic patients to provide stationary anchorage for front teeth retraction. Group 1: 20 tapered self-drilling miniscrews, Group 2: 20 cylindrical self-drilling miniscrew. Split mouth technique was used. All of the TADs were inserted parallel to the occlusal plane, between roots of the 2nd maxillary premolar and 1st maxillary molar. The TADs were immediately loaded with constant and continuous load using 8 mm long heavy short Nickel Titanium coil spring. The coil spring was stretched between the heads of the two types of TADs and crimpable hooks that fixed on arch wire just distal to the anterior six maxillary teeth. After complete retraction of the anterior maxillary teeth, TADs were removed using torque adjustable screw-removal. At the moment of movement of the TAD the torque was recorded in Newton Centimeter (Ncm). Results: Mann Whitney U Test resulted in a significant difference between the two groups, indicating that cylindrical TADs had significantly higher removal torque than tapered TADs (means were 3.20 Ncm ± 0.20 and 2.70 Ncm ± 0.10 respectively). Conclusion: Physical properties have a considerable influence on the stability of the TADs. Cylindrical TADs are showed more mechanical interlock into the bone.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种自钻孔正畸临时支抗装置的移除力矩分析
微型支架或临时锚固装置(TADs)的稳定性是正畸治疗中成功应用的关键因素。微螺杆拆卸扭矩可作为微螺杆稳定性的指标。这项工作的目的是比较自钻锥形微型螺钉和圆柱形微型螺钉之间的拆卸扭矩。材料与方法:将两组TADs植入正畸患者的上颌,为前牙后缩提供固定支抗。第一组:锥形自钻微型螺钉20个,第二组:圆柱形自钻微型螺钉20个。采用裂口法。所有TADs均平行于咬合平面插入,位于上颌第2前磨牙根与第1上颌磨牙根之间。使用8mm长、重、短镍钛线圈弹簧,立即对TADs进行恒定和连续加载。线圈弹簧在两种TADs的头部之间拉伸,可卷曲钩固定在前六颗上颌牙齿远端的弓丝上。上颌前牙完全缩回后,采用扭矩可调螺钉拔除TADs。在TAD的运动时刻,以牛顿厘米(Ncm)为单位记录扭矩。结果:Mann Whitney U检验结果显示两组间存在显著差异,圆柱形TADs的去除扭矩明显高于锥形TADs(平均值分别为3.20 Ncm±0.20和2.70 Ncm±0.10)。结论:物理性质对TADs的稳定性有较大影响。圆柱形TADs与骨骼的机械互锁性更强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dentin Disinfection Efficacy Using Four Different Irrigation Protocols Assessment of Oral Health Care and Knowledge amongst University Students Application of IARTI and Ameliorating Principles to Improve Compliance and Completion of Treatment in General Dental Practice Management of Mandibular Fractures: Report of Three Cases Comparative Evaluation of the Efficacy of Silver Diamine Fluoride, Sodium Fluoride and GC Tooth Mousse Plus and Fluoride Varnish as an Antibacterial Agent in Childhood Caries: As a Literature Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1