{"title":"Development of 450 kVA triport UPS system","authors":"Y. Kawata, H. Koike, F. Tominaga, T. Nakamizo, K. Harada","doi":"10.1109/INTLEC.1988.22403","DOIUrl":null,"url":null,"abstract":"The development of a triport UPS (uninterruptible power system) rated at 450 kVA in three-phase that combines three units of triport UPSs, each rated at 150 kVA in three-phase, in parallel connection has been completed. With multiple units of triport UPSs running in parallel, the rule of proportionality to kVA's can be true for load distribution and it simplifies the design of a system containing them for parallel operation. The authors describe the properties of the triad triport UPS, including load distribution characteristics, an inverter synchronization circuit, and a defective-unit exclusion circuit.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"10th International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1988.22403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The development of a triport UPS (uninterruptible power system) rated at 450 kVA in three-phase that combines three units of triport UPSs, each rated at 150 kVA in three-phase, in parallel connection has been completed. With multiple units of triport UPSs running in parallel, the rule of proportionality to kVA's can be true for load distribution and it simplifies the design of a system containing them for parallel operation. The authors describe the properties of the triad triport UPS, including load distribution characteristics, an inverter synchronization circuit, and a defective-unit exclusion circuit.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
450kva三相UPS系统的研制
一种额定450kva三相三相不间断UPS(不间断电源系统)的开发已经完成,该系统将三个额定150kva三相三相三相三相UPS并联在一起。对于并联运行的多台三相ups,与kVA的比例规则可以适用于负载分配,并且简化了包含并联运行的系统的设计。作者描述了三合一三端口UPS的特性,包括负载分布特性、逆变器同步电路和缺陷单元排除电路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Conversion of constant current to constant voltage by high-frequency resonant converter Design for a highly efficient distributed power supply system based on reliability analysis Redundant DC-DC switching power supply system for telecommunication equipment The quality required in electrolyte limited, valve regulated lead-acid batteries for telecommunication systems Spectral analysis of input currents of delta PWM converters using discrete Fourier transform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1