10th International Telecommunications Energy Conference最新文献

英文 中文
Conversion of constant current to constant voltage by high-frequency resonant converter 用高频谐振变换器将恒流转换为恒压
Pub Date : 1988-12-01 DOI: 10.1109/INTLEC.1988.22353
T. Ninomiya, T. Higashi, K. Harada
A high-frequency resonant converter with constant-current input is investigated analytically and experimentally. This converter can step up the input current and convert it into the constant voltage which is used in ordinary electronic equipment. It is useful for supplying electronic equipment which is located far from the power source and is required to be remotely supplied with a low-voltage and high-current electric power. The static characteristics of this voltage-mode resonant converter are analyzed, and the dynamic characteristics and the high-frequency operation in the megahertz range are examined experimentally.<>
对恒流输入高频谐振变换器进行了分析和实验研究。这种变换器可以将输入电流升压,并将其转换成普通电子设备中使用的恒压。它适用于为远离电源的电子设备供电,需要远程提供低压大电流的电力。分析了该电压型谐振变换器的静态特性,并对其动态特性和兆赫范围内的高频工作特性进行了实验研究。
{"title":"Conversion of constant current to constant voltage by high-frequency resonant converter","authors":"T. Ninomiya, T. Higashi, K. Harada","doi":"10.1109/INTLEC.1988.22353","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22353","url":null,"abstract":"A high-frequency resonant converter with constant-current input is investigated analytically and experimentally. This converter can step up the input current and convert it into the constant voltage which is used in ordinary electronic equipment. It is useful for supplying electronic equipment which is located far from the power source and is required to be remotely supplied with a low-voltage and high-current electric power. The static characteristics of this voltage-mode resonant converter are analyzed, and the dynamic characteristics and the high-frequency operation in the megahertz range are examined experimentally.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"98 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115171855","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Design for a highly efficient distributed power supply system based on reliability analysis 基于可靠性分析的高效分布式供电系统设计
Pub Date : 1988-12-01 DOI: 10.1109/INTLEC.1988.22406
K. Yotsumoto, S. Muroyama, S. Matsumura, H. Watanabe
A distributed power supply system with highly efficient characteristics is being developed to replace conventional centralized power systems. In this system, as in conventional power systems, a standby energy system composed of batteries and engine-generator sets is used as a back-up system for the commercial power lines. However, the distributed power system, except for the engine-generator set, is installed in the telecommunications room. Thus, the floor load limitation is an important design factor. Reliability analyses show that the distributed power system should be designed using a fully duplicated engine-generator set; with battery reserve time reduced to one-sixth that of conventional centralized power systems; and with transfer switch unavailability designed to be less than 5*10/sup -7/.<>
一种高效的分布式供电系统正在发展,以取代传统的集中式供电系统。在这个系统中,与传统的电力系统一样,由电池和发动机发电机组组成的备用能源系统被用作商业电力线的备用系统。但是,除发电机组外,分布式电力系统均安装在电信机房内。因此,楼板荷载限制是一个重要的设计因素。可靠性分析表明,分布式电力系统应采用完全复制的机-发电机组设计;电池储备时间缩短至传统集中式电力系统的六分之一;带转换开关的不可用性设计为小于5*10/sup -7/ >
{"title":"Design for a highly efficient distributed power supply system based on reliability analysis","authors":"K. Yotsumoto, S. Muroyama, S. Matsumura, H. Watanabe","doi":"10.1109/INTLEC.1988.22406","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22406","url":null,"abstract":"A distributed power supply system with highly efficient characteristics is being developed to replace conventional centralized power systems. In this system, as in conventional power systems, a standby energy system composed of batteries and engine-generator sets is used as a back-up system for the commercial power lines. However, the distributed power system, except for the engine-generator set, is installed in the telecommunications room. Thus, the floor load limitation is an important design factor. Reliability analyses show that the distributed power system should be designed using a fully duplicated engine-generator set; with battery reserve time reduced to one-sixth that of conventional centralized power systems; and with transfer switch unavailability designed to be less than 5*10/sup -7/.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129530158","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
Telephone line circuit DC-to-DC converter 电话线电路dc - dc转换器
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22326
D. Gradl, J. Krueger, S. Henning
A unique, low-power, DC-to-DC switching converter has been developed to provided DC power for analog telephone lines. The converter uses a flyback configuration with a nonlinear element in one of two separate feedback loops. The feedback provides a dual mode of operation with constant voltage output for low-load currents and limited power output for high-load currents. This allows a simple, versatile circuit configuration that is well suited to telephone-line-feed applications. Its output characteristics cannot be reproduced with conventional linear techniques or switching converter techniques. The authors provide background information on the design of the converter and describe the operation of the converter at the functional block level. They describe the overall circuit features and characteristics of the line-feed application as well as circuit implementation and practical considerations. Finally, laboratory test results are presented.<>
一种独特的、低功率的DC- DC开关转换器已经开发出来,为模拟电话线提供直流电源。该变换器采用反激式结构,在两个独立的反馈回路中有一个非线性元件。反馈提供了双工作模式,低负载电流时输出恒压,高负载电流时输出有限功率。这允许一个简单的,通用的电路配置,非常适合电话线馈电应用。它的输出特性不能用传统的线性技术或开关变换器技术再现。作者提供了转换器设计的背景资料,并描述了转换器在功能块级的操作。它们描述了整个电路的特点和馈线应用的特点,以及电路的实现和实际考虑。最后给出了实验室测试结果
{"title":"Telephone line circuit DC-to-DC converter","authors":"D. Gradl, J. Krueger, S. Henning","doi":"10.1109/INTLEC.1988.22326","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22326","url":null,"abstract":"A unique, low-power, DC-to-DC switching converter has been developed to provided DC power for analog telephone lines. The converter uses a flyback configuration with a nonlinear element in one of two separate feedback loops. The feedback provides a dual mode of operation with constant voltage output for low-load currents and limited power output for high-load currents. This allows a simple, versatile circuit configuration that is well suited to telephone-line-feed applications. Its output characteristics cannot be reproduced with conventional linear techniques or switching converter techniques. The authors provide background information on the design of the converter and describe the operation of the converter at the functional block level. They describe the overall circuit features and characteristics of the line-feed application as well as circuit implementation and practical considerations. Finally, laboratory test results are presented.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115545175","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Stability improvement of constant voltage transformer for triport UPS system 三相UPS系统恒压变压器的稳定性改进
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22404
K. Harada, Y. Ji, Y. Katayama, C.J. Chen, T. Nakamizo
A novel method for improving the stability of the AVR (automatic voltage regulator) constant voltage transformer for triport UPS (uninterruptible power supply) systems is introduced. An active filter with an operational amplifier as the feedback element for controlling the AVR is shown to reduce the system instability; this device is more compact and economical than the alternative magnetic feedback amplifier. Experimental and simulation results demonstrate the effectiveness of active filter feedback of a higher order for suppressing the instability.<>
介绍了一种提高三相不间断电源系统中AVR(自动调压器)恒压变压器稳定性的新方法。采用运放作为控制AVR的反馈元件的有源滤波器可以降低系统的不稳定性;该装置比备选磁反馈放大器更紧凑、更经济。实验和仿真结果验证了高阶有源滤波反馈对抑制不稳定性的有效性。
{"title":"Stability improvement of constant voltage transformer for triport UPS system","authors":"K. Harada, Y. Ji, Y. Katayama, C.J. Chen, T. Nakamizo","doi":"10.1109/INTLEC.1988.22404","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22404","url":null,"abstract":"A novel method for improving the stability of the AVR (automatic voltage regulator) constant voltage transformer for triport UPS (uninterruptible power supply) systems is introduced. An active filter with an operational amplifier as the feedback element for controlling the AVR is shown to reduce the system instability; this device is more compact and economical than the alternative magnetic feedback amplifier. Experimental and simulation results demonstrate the effectiveness of active filter feedback of a higher order for suppressing the instability.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116539765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
The effect of solar radiation and wind speed on air temperature rise in outdoor cabinets containing telephone equipment 太阳辐射和风速对室外电话机柜内空气温升的影响
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22363
J. McKay
A series of tests is being conducted to explore various methods for economically controlling the temperature within small metal cabinets housing telephone equipment. Initial tests focus on measurement of the temperature rise in unventilated cabinets as a function of internal heat load, outdoor ambient conditions and the use of internal air circulating fans. An AT&T Community Service Cabinet, Type 80-C, was used as the test vehicle in these tests. The author reports the results from the initial test series. Among other results, it is shown that internal heat generated within the cabinet is more important than solar radiation in the air temperature rise.<>
正在进行一系列试验,以探索各种经济地控制电话设备小金属柜内温度的方法。初始测试侧重于测量不通风机柜内温升作为内部热负荷、室外环境条件和使用内部空气循环风机的函数。在这些测试中,使用AT&T的80-C型社区服务柜作为测试工具。作者报告了最初试验系列的结果。在其他结果中,表明柜内产生的内部热量比太阳辐射在空气温度上升中更重要。
{"title":"The effect of solar radiation and wind speed on air temperature rise in outdoor cabinets containing telephone equipment","authors":"J. McKay","doi":"10.1109/INTLEC.1988.22363","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22363","url":null,"abstract":"A series of tests is being conducted to explore various methods for economically controlling the temperature within small metal cabinets housing telephone equipment. Initial tests focus on measurement of the temperature rise in unventilated cabinets as a function of internal heat load, outdoor ambient conditions and the use of internal air circulating fans. An AT&T Community Service Cabinet, Type 80-C, was used as the test vehicle in these tests. The author reports the results from the initial test series. Among other results, it is shown that internal heat generated within the cabinet is more important than solar radiation in the air temperature rise.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126540143","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Reliability and availability performance as a tool to optimize power systems 可靠性和可用性性能作为优化电力系统的工具
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22324
T. Suntio, K. White
The authors describe by means of a case study how the reliability and availability performance can be utilized to obtain the optimal solution for uninterruptible power supplies (UPS) from the power systems user's point of view. It is concluded that UPS power systems cannot be optimized if the defined acceptable risk level is not well or not at all defined. In addition, it is noted that optimization is difficult or almost impossible if the reliability and availability performance philosophy and methods are not used or not understood.<>
通过一个案例研究,阐述了如何从电力系统用户的角度出发,利用可靠性和可用性性能来获得不间断电源(UPS)的最优解决方案。结论是,如果定义的可接受风险水平没有很好地定义或根本没有定义,则UPS电力系统无法优化。此外,需要注意的是,如果不使用或不理解可靠性和可用性性能理念和方法,则很难或几乎不可能进行优化
{"title":"Reliability and availability performance as a tool to optimize power systems","authors":"T. Suntio, K. White","doi":"10.1109/INTLEC.1988.22324","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22324","url":null,"abstract":"The authors describe by means of a case study how the reliability and availability performance can be utilized to obtain the optimal solution for uninterruptible power supplies (UPS) from the power systems user's point of view. It is concluded that UPS power systems cannot be optimized if the defined acceptable risk level is not well or not at all defined. In addition, it is noted that optimization is difficult or almost impossible if the reliability and availability performance philosophy and methods are not used or not understood.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134550667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Telecommunications powering system 电信供电系统
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22346
Y. Ueki, T. Washio
The authors describe the concept of a powering system for communications network systems and shows its application. The concept involves the integration of the -48 V main power supply and DC-DC converters that form the present powering system used in switching systems. This will eliminate the main power supply, decentralize equipment, and make the system more compact and efficient. In addition, this system is characterized by high efficiency, high reliability, ease of installation, expansibility, and safety.<>
介绍了通信网络供电系统的概念及其应用。这个概念涉及到- 48v主电源和DC-DC转换器的集成,它们构成了目前在开关系统中使用的供电系统。这将消除主电源,分散设备,使系统更加紧凑和高效。此外,该系统还具有效率高、可靠性高、安装方便、可扩展性强、安全性高等特点。
{"title":"Telecommunications powering system","authors":"Y. Ueki, T. Washio","doi":"10.1109/INTLEC.1988.22346","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22346","url":null,"abstract":"The authors describe the concept of a powering system for communications network systems and shows its application. The concept involves the integration of the -48 V main power supply and DC-DC converters that form the present powering system used in switching systems. This will eliminate the main power supply, decentralize equipment, and make the system more compact and efficient. In addition, this system is characterized by high efficiency, high reliability, ease of installation, expansibility, and safety.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114950754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Thermal control wall for telecommunication equipment rooms 电信机房热控墙
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22362
M. Nakao, K. Ohshima, H. Jitsukawa
The authors describe the feature and operation of the thermal control wall (TCW) system, which combines an exterior wall and cooling system. It can vary its heat transmission coefficient from one to ten times that of an ordinary wall. The TCW cools rooms efficiently, using cool outer air during the winter. The TCW can decrease the load on air conditions if used jointly with them, and save energy as a result. The TCW, which has been installed in a telecommunications office building, is estimated to save 20% of annual cooling energy, according to actual data.<>
介绍了外墙与冷却系统相结合的热控墙系统的特点和工作原理。它的传热系数是普通墙体的一到十倍。TCW在冬季利用凉爽的外部空气有效地冷却房间。TCW与空调联用可减少空调负荷,节约能源。据实际数据显示,安装在一座电信办公大楼内的TCW预计每年可节省20%的冷却能源。
{"title":"Thermal control wall for telecommunication equipment rooms","authors":"M. Nakao, K. Ohshima, H. Jitsukawa","doi":"10.1109/INTLEC.1988.22362","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22362","url":null,"abstract":"The authors describe the feature and operation of the thermal control wall (TCW) system, which combines an exterior wall and cooling system. It can vary its heat transmission coefficient from one to ten times that of an ordinary wall. The TCW cools rooms efficiently, using cool outer air during the winter. The TCW can decrease the load on air conditions if used jointly with them, and save energy as a result. The TCW, which has been installed in a telecommunications office building, is estimated to save 20% of annual cooling energy, according to actual data.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129759684","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A revised approach to hybrid system design 混合动力系统设计的修正方法
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22390
S. Samuelsen, B.R. Bredesen
The Norwegian Telecommunications Administration (NTA) has developed a revised approach to hybrid power-system design using wind generators to power telecommunications systems in remote areas. The authors describe the techniques and methods adopted and the expected results form this revised design. The focus has fallen on improving the utilization of waste heat from the fuel-fired part of the power system and providing better accessibility for service and maintenance. The renewable power part, namely the wind generators, have been particularly difficult to service during icy/windy weather conditions, when climbing towers can become quite a hazard. To overcome this problem, towers have been designed to allow for servicing without climbing. The BARK project at Sprinklerfjell, being put into operation in January 1988, will be the southern-most operated within the NTA Qualification Test Program with the least favorable access to natural (wind) energy.<>
挪威电信管理局(NTA)开发了一种改进的混合电力系统设计方法,利用风力发电机为偏远地区的电信系统供电。作者描述了采用的技术和方法以及修改后设计的预期结果。重点是改进对电力系统燃料部分的废热的利用,并提供更好的服务和维修。可再生能源部分,即风力发电机,在结冰/多风的天气条件下尤其难以维修,因为爬塔可能会成为相当危险的事情。为了克服这个问题,塔楼的设计允许在不爬升的情况下进行维修。位于Sprinklerfjell的BARK项目将于1988年1月投入运行,它将是NTA资格测试计划中最南端运行的项目,也是获得自然(风能)最不利的项目。
{"title":"A revised approach to hybrid system design","authors":"S. Samuelsen, B.R. Bredesen","doi":"10.1109/INTLEC.1988.22390","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22390","url":null,"abstract":"The Norwegian Telecommunications Administration (NTA) has developed a revised approach to hybrid power-system design using wind generators to power telecommunications systems in remote areas. The authors describe the techniques and methods adopted and the expected results form this revised design. The focus has fallen on improving the utilization of waste heat from the fuel-fired part of the power system and providing better accessibility for service and maintenance. The renewable power part, namely the wind generators, have been particularly difficult to service during icy/windy weather conditions, when climbing towers can become quite a hazard. To overcome this problem, towers have been designed to allow for servicing without climbing. The BARK project at Sprinklerfjell, being put into operation in January 1988, will be the southern-most operated within the NTA Qualification Test Program with the least favorable access to natural (wind) energy.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129011407","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A microprocessor based controller for remote site PV systems including hardware design criteria and advanced control algorithms 基于微处理器的远程现场光伏系统控制器,包括硬件设计标准和先进的控制算法
Pub Date : 1988-10-30 DOI: 10.1109/INTLEC.1988.22376
D. Danley, K. Gerken
The authors evaluate the performance of a microprocessor-based controller developed for remote-site photovoltaic (PV) systems. They also review ongoing advances in the concept of intelligent controls. It is concluded that a reliable microprocessor-based power system controller offers significant advantages over analog controls for remote site PV and PV hybrid systems. The digital control logic allows customization in software rather than hardware, and expansion capabilities provide for the ability to control more complex power systems anticipated in the future.<>
作者评估了一种基于微处理器的远程光伏(PV)系统控制器的性能。他们还回顾了智能控制概念的持续进展。结论是,可靠的基于微处理器的电力系统控制器为远程站点PV和PV混合系统提供了比模拟控制显著的优势。数字控制逻辑允许在软件而不是硬件上进行定制,并且扩展能力提供了控制未来预期的更复杂电力系统的能力。
{"title":"A microprocessor based controller for remote site PV systems including hardware design criteria and advanced control algorithms","authors":"D. Danley, K. Gerken","doi":"10.1109/INTLEC.1988.22376","DOIUrl":"https://doi.org/10.1109/INTLEC.1988.22376","url":null,"abstract":"The authors evaluate the performance of a microprocessor-based controller developed for remote-site photovoltaic (PV) systems. They also review ongoing advances in the concept of intelligent controls. It is concluded that a reliable microprocessor-based power system controller offers significant advantages over analog controls for remote site PV and PV hybrid systems. The digital control logic allows customization in software rather than hardware, and expansion capabilities provide for the ability to control more complex power systems anticipated in the future.<<ETX>>","PeriodicalId":169486,"journal":{"name":"10th International Telecommunications Energy Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1988-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125519372","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
10th International Telecommunications Energy Conference
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1