Adam A. Wilson, T. Borca-Tasciuc, Hong Wang, Choongho Yu
{"title":"Thermal conductivity of double-wall carbon nanotube-polyanaline composites measured by a non-contact scanning hot probe technique","authors":"Adam A. Wilson, T. Borca-Tasciuc, Hong Wang, Choongho Yu","doi":"10.1109/ITHERM.2017.8023959","DOIUrl":null,"url":null,"abstract":"This paper presents a method for determining thermal conductivity of film samples using the non-contact mode scanning hot probe technique at probe-to-sample distances such that Fourier law heat conduction across the air gap occurs. A method for calibrating non-contact thermal exchange parameters between probe and sample using a single reference sample is proposed and the obtained value of sample thermal conductivity is presented for thin film samples of PANI-CSA infused with varying concentrations of DW-CNTs. Two- to three-fold increase in film thermal conductivity (from 0.4 Wm-1K-1) for the un-doped polymer to 0.8-1.1 Wm-1K-1) is observed for DW-CNT concentration of less than 20% by weight, and a more than seven-fold increase (3.0 Wm-1K-1) is reported for DW-CNT concentration of 30% by weight.","PeriodicalId":387542,"journal":{"name":"2017 16th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 16th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.2017.8023959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
This paper presents a method for determining thermal conductivity of film samples using the non-contact mode scanning hot probe technique at probe-to-sample distances such that Fourier law heat conduction across the air gap occurs. A method for calibrating non-contact thermal exchange parameters between probe and sample using a single reference sample is proposed and the obtained value of sample thermal conductivity is presented for thin film samples of PANI-CSA infused with varying concentrations of DW-CNTs. Two- to three-fold increase in film thermal conductivity (from 0.4 Wm-1K-1) for the un-doped polymer to 0.8-1.1 Wm-1K-1) is observed for DW-CNT concentration of less than 20% by weight, and a more than seven-fold increase (3.0 Wm-1K-1) is reported for DW-CNT concentration of 30% by weight.