Chang Liu, Ashkan Ghanbarzadeh-Dagheyan, J. Heredia-Juesas, A. Molaei, J. Martinez-Lorenzo
{"title":"The Study of Holey Cavity in the Application of Thermoacoustics Imaging","authors":"Chang Liu, Ashkan Ghanbarzadeh-Dagheyan, J. Heredia-Juesas, A. Molaei, J. Martinez-Lorenzo","doi":"10.1115/IMECE2018-87757","DOIUrl":null,"url":null,"abstract":"Microwave-induced Thermoacoustics (TA) sensing has the potential to be a breakthrough in subsurface imaging applications. This is because it combines the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging. However, state-of-the-art TA hardware requires that the receiving transducer is scanned in a linear or rotational fashion in order to be able to collect enough orthogonal data needed to produce a TA image possessing high-spatial resolution both in range and cross-range. This process is slow, increases the detection time, and adds an extra complexity to the system. In order to address these problems, a Compressive Sensing (CS) methodology is presented in this paper as a mechanism to reduce the minimum number of data samples required to reconstruct a sparse signal. Furthermore, in order to reduce the mutual information shared by different measurements, a holey cavity structure is proposed to be used to perform 4D coding. In this work, the TA imaging theory is introduced; and the impact that the holey cavity parameters have in the imaging performance is studied. The imaging results in this work are carried out using a distributed Alternating Direction Method of Multipliers (ADMM) algorithm, capable of using norm-1 and norm-2 regularizers; and they reveal the effectiveness of the proposed holey-cavity and CS TA imaging approach.","PeriodicalId":197121,"journal":{"name":"Volume 11: Acoustics, Vibration, and Phononics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 11: Acoustics, Vibration, and Phononics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/IMECE2018-87757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Microwave-induced Thermoacoustics (TA) sensing has the potential to be a breakthrough in subsurface imaging applications. This is because it combines the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging. However, state-of-the-art TA hardware requires that the receiving transducer is scanned in a linear or rotational fashion in order to be able to collect enough orthogonal data needed to produce a TA image possessing high-spatial resolution both in range and cross-range. This process is slow, increases the detection time, and adds an extra complexity to the system. In order to address these problems, a Compressive Sensing (CS) methodology is presented in this paper as a mechanism to reduce the minimum number of data samples required to reconstruct a sparse signal. Furthermore, in order to reduce the mutual information shared by different measurements, a holey cavity structure is proposed to be used to perform 4D coding. In this work, the TA imaging theory is introduced; and the impact that the holey cavity parameters have in the imaging performance is studied. The imaging results in this work are carried out using a distributed Alternating Direction Method of Multipliers (ADMM) algorithm, capable of using norm-1 and norm-2 regularizers; and they reveal the effectiveness of the proposed holey-cavity and CS TA imaging approach.