Evaluation of currents and charges in low-voltage surge arresters due to lightning strikes

W Bassi, J. M. Janiszewski
{"title":"Evaluation of currents and charges in low-voltage surge arresters due to lightning strikes","authors":"W Bassi, J. M. Janiszewski","doi":"10.1109/MPER.2002.4312515","DOIUrl":null,"url":null,"abstract":"Summary form only given, as follows. This paper presents an evaluation of the values of currents and charges absorbed by surge protective devices (SPDs) connected in low-voltage open-wire overhead distribution networks in the case of direct lightning strikes to primary lines. Also, some information about overvoltages magnitude is included. The calculations have been performed using the ATP (Alternative Transients Program). The modeling of the system components includes the insulation characteristics (voltage versus time to breakdown) of the primary and secondary insulators and a distribution transformer model for high frequencies which takes into account the load conditions. Some parameters of interest are taken into consideration in the analysis, such as ground resistances of poles and consumers, lightning strike position and crest value of the stroke current.","PeriodicalId":117177,"journal":{"name":"IEEE Power Engineering Society Summer Meeting,","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Engineering Society Summer Meeting,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MPER.2002.4312515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Summary form only given, as follows. This paper presents an evaluation of the values of currents and charges absorbed by surge protective devices (SPDs) connected in low-voltage open-wire overhead distribution networks in the case of direct lightning strikes to primary lines. Also, some information about overvoltages magnitude is included. The calculations have been performed using the ATP (Alternative Transients Program). The modeling of the system components includes the insulation characteristics (voltage versus time to breakdown) of the primary and secondary insulators and a distribution transformer model for high frequencies which takes into account the load conditions. Some parameters of interest are taken into consideration in the analysis, such as ground resistances of poles and consumers, lightning strike position and crest value of the stroke current.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
雷电对低压避雷器中电流和电荷的评估
仅给出摘要形式,如下。本文介绍了在一次线路遭受直接雷击的情况下,连接在低压开线架空配电网中的浪涌保护装置(spd)所吸收的电流和电荷值的评估。此外,还包括有关过电压幅度的一些信息。计算使用ATP(可选瞬态程序)进行。系统组件的建模包括初级和次级绝缘子的绝缘特性(电压与击穿时间的关系)以及考虑负载条件的高频配电变压器模型。在分析中考虑了一些重要的参数,如极和消费者的接地电阻、雷击位置和冲击电流的峰值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
New algorithm to phase selection based on wavelet transforms A parameter identification technique for metal-oxide surge arrester models Dynamic security enhancement in power-market systems Evaluation of currents and charges in low-voltage surge arresters due to lightning strikes Local area spatial load forecasting at NSTAR
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1