Kun Wang, Lianke Xie, Yidan Zhu, Hongbing Su, Dandan Dou, Guoying Zhang
{"title":"Frequency spectrum analysis and control technology analysis of converter noise in substation","authors":"Kun Wang, Lianke Xie, Yidan Zhu, Hongbing Su, Dandan Dou, Guoying Zhang","doi":"10.1117/12.2667921","DOIUrl":null,"url":null,"abstract":"In order to analyze the noise spectrum of converter substation and control the occupational exposure noise of operators at an acceptable level, this paper makes field measurement and spectrum analysis of occupational exposure noise of converter transformers, converter valve halls, AC filters and other operators in converter substations with different voltage levels. The results show that the noise energy of converter substation is mainly concentrated in the middle and low frequencies, and the sound pressure level of the line spectrum with even frequency doubling of 50Hz is prominent, and the frequency is concentrated in the frequency range of 100 ~ 1000 Hz. Except that the energy of the valve hall is still high at the high frequency, the sound pressure level of noise in other workplaces almost drops below 50dB when the frequency is higher than 5kHz. Based on this feature, noise control measures are put forward from three aspects: sound source control, sound insulation control and personnel protection.","PeriodicalId":227067,"journal":{"name":"International Conference on Precision Instruments and Optical Engineering","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Precision Instruments and Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2667921","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In order to analyze the noise spectrum of converter substation and control the occupational exposure noise of operators at an acceptable level, this paper makes field measurement and spectrum analysis of occupational exposure noise of converter transformers, converter valve halls, AC filters and other operators in converter substations with different voltage levels. The results show that the noise energy of converter substation is mainly concentrated in the middle and low frequencies, and the sound pressure level of the line spectrum with even frequency doubling of 50Hz is prominent, and the frequency is concentrated in the frequency range of 100 ~ 1000 Hz. Except that the energy of the valve hall is still high at the high frequency, the sound pressure level of noise in other workplaces almost drops below 50dB when the frequency is higher than 5kHz. Based on this feature, noise control measures are put forward from three aspects: sound source control, sound insulation control and personnel protection.