Use of Model-Free and Zero-Setup ComputerGuided Implant Surgical Template for Partial Edentulous Cases

Bongchun Hur, K. Oh, June-Sung Shim, Ji-Man Park
{"title":"Use of Model-Free and Zero-Setup ComputerGuided Implant Surgical Template for Partial Edentulous Cases","authors":"Bongchun Hur, K. Oh, June-Sung Shim, Ji-Man Park","doi":"10.32542/implantology.2019019","DOIUrl":null,"url":null,"abstract":"This case report presents the cases of single anterior missing and posterior free-end edentulous ridge with computer-guided implant placement on the day of visit through a special tray containing fiducial markers without model scan or intraoral scan data. Cone beam CT was taken after fixing the marker embedded ready-made tray with a photopolymerized resin material by light-curing in the patient's mouth. The implant location was planned on the registered CT data in the planning software. The tool path calculation for the milling machine was conducted in the computer-aided manufacture (CAM) software. The guide was completed by milling the drill hole in the special tray as designed. Although the preparation for the conventional implant guide surgery takes considerable time, including data acquisition and 3D printing, it was possible to produce a guide on the day of the patient visit without a separate procedure other than a CT scan through this protocol. Also, the transfer of the implant surgery plan, the process of scanning and 3D printing, was omitted, thereby reducing the positional error between the CT data and the actual guide.","PeriodicalId":370954,"journal":{"name":"The Korean Academy of Oral and Maxillofacial Implantology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Korean Academy of Oral and Maxillofacial Implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32542/implantology.2019019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This case report presents the cases of single anterior missing and posterior free-end edentulous ridge with computer-guided implant placement on the day of visit through a special tray containing fiducial markers without model scan or intraoral scan data. Cone beam CT was taken after fixing the marker embedded ready-made tray with a photopolymerized resin material by light-curing in the patient's mouth. The implant location was planned on the registered CT data in the planning software. The tool path calculation for the milling machine was conducted in the computer-aided manufacture (CAM) software. The guide was completed by milling the drill hole in the special tray as designed. Although the preparation for the conventional implant guide surgery takes considerable time, including data acquisition and 3D printing, it was possible to produce a guide on the day of the patient visit without a separate procedure other than a CT scan through this protocol. Also, the transfer of the implant surgery plan, the process of scanning and 3D printing, was omitted, thereby reducing the positional error between the CT data and the actual guide.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无模型和零设置计算机引导种植手术模板在部分无牙病例中的应用
本病例报告介绍了单个前牙缺失和后牙游离端无牙嵴的病例,在没有模型扫描或口内扫描数据的情况下,通过包含基准标记的特殊托盘在访问当天通过计算机引导种植体放置。用光聚合树脂材料将标记物嵌入的现成托盘光固化固定在患者口腔内,取锥束CT。在规划软件中根据注册的CT数据规划种植体位置。在计算机辅助制造(CAM)软件中对铣床的刀具轨迹进行了计算。根据设计,通过在特殊托盘上铣削钻头孔来完成导轨。虽然传统的种植指南手术的准备工作需要相当长的时间,包括数据采集和3D打印,但根据该方案,除了CT扫描外,无需其他单独的程序,就可以在患者就诊当天制作指南。并且省去了植入手术方案的转移,即扫描和3D打印的过程,从而减少了CT数据与实际导轨之间的位置误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study Comparison of Mechanical Properties of Milled and Casted Cobalt-Chromium Alloys Using Three-point Bending Test Atraumatic Removal of Displaced Implant in the Fatty Bony Marrow Orocutaneous Fistula after Implant Placement with Sinus Floor Elevation via Transalveolar Approach: A Case Report Fabricating an Implant-Supported Crown with Impression Scanning Technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1