{"title":"Analysis of composite power quality events using s-transform","authors":"D. Saxena, S. Singh, K. Verma","doi":"10.1109/ISGT-ASIA.2012.6303357","DOIUrl":null,"url":null,"abstract":"This paper demonstrates the effectiveness of S-transform in detecting and classifying multiple/composite power quality (PQ) events compared to the discrete wavelet transform for the accuracy of tracking the amplitude and frequency changes. Five different types of multiple/composite disturbance signals are considered, in this paper, including harmonics with voltage sag, harmonics with voltage swell, impulsive transient with harmonics, harmonics with notches, harmonics with voltage sag corrupted with noise. Analysis of different multiple PQ events to extract the quantitative features like time, frequency and amplitude of each disturbance clearly shows that the S-transform method is insensitive to noise and proves to be more accurate and effective as compared to wavelet transform.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper demonstrates the effectiveness of S-transform in detecting and classifying multiple/composite power quality (PQ) events compared to the discrete wavelet transform for the accuracy of tracking the amplitude and frequency changes. Five different types of multiple/composite disturbance signals are considered, in this paper, including harmonics with voltage sag, harmonics with voltage swell, impulsive transient with harmonics, harmonics with notches, harmonics with voltage sag corrupted with noise. Analysis of different multiple PQ events to extract the quantitative features like time, frequency and amplitude of each disturbance clearly shows that the S-transform method is insensitive to noise and proves to be more accurate and effective as compared to wavelet transform.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于s变换的复合电能质量事件分析
与离散小波变换相比,本文证明了s变换在检测和分类多/复合电能质量(PQ)事件方面的有效性,以跟踪振幅和频率变化的准确性。本文考虑了五种不同类型的多重/复合干扰信号,包括带电压跌落的谐波、带电压膨胀的谐波、带脉冲暂态谐波、带缺口的谐波、带噪声的电压跌落谐波。通过对不同的多个PQ事件进行分析,提取各扰动的时间、频率、幅度等定量特征,表明s变换方法对噪声不敏感,比小波变换更准确有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wind-photovoltaic-storage system optimal control scheme based on generation scheduling Smart grid oriented smart substation characteristics analysis Studies on practical Small Signal Stability Region of electrical power systems A survey of communication technology in distribution network An interior point method based on continuous Newton's method for optimal power flow
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1