Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability

J. Seidel, J. J. Vaquero, Michael V. Green
{"title":"Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability","authors":"J. Seidel, J. J. Vaquero, Michael V. Green","doi":"10.1109/NSSMIC.2001.1008634","DOIUrl":null,"url":null,"abstract":"PET scanners designed to image animals the size of rats and mice should possess simultaneously high and uniform spatial resolution and high sensitivity. ATLAS (Advanced Technology Laboratory Animal Scanner), an 11.8 cm diameter aperture, 2 cm axial field-of-view ring-type research scanner seeks these goals by surrounding the animal with eighteen 15 mm deep, LGSO (7 mm)/GSO (8 mm) phoswich detector modules. A Monte Carlo simulation was used to compare the variation of resolution across the field-of-view and the absolute central point source sensitivity (ACS) of ATLAS to similar systems comprised only of LSO arrays of different depths with no depth-of-interaction (DOI) capability. For ATLAS radial spatial resolution deteriorated by 27% from the center to 3 cm off-axis. Scanners comprised of 15 mm deep, 10 mm deep and 7 mm deep LSO crystals deteriorated by 100%, 51%, and 20% respectively, over the same distance. Simulated ACS (absorbed energies /spl ges/250 keV) for ATLAS was 2.0% and for the 15 mm, 10 mm deep and 7 mm deep LSO scanners 2.4%, 1.5%, and 0.9%, respectively. Radial resolution loss 3 cm off-axis and ACS measured for the actual ATLAS scanner were similar to the values obtained by simulation (27% resolution loss, 1.8% ACS). The phoswich design thus achieves good resolution uniformity over a 6 cm FOV while preserving sensitivity compared to equivalent non-DOI LSO scanners with a range of crystal depths.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"188","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 188

Abstract

PET scanners designed to image animals the size of rats and mice should possess simultaneously high and uniform spatial resolution and high sensitivity. ATLAS (Advanced Technology Laboratory Animal Scanner), an 11.8 cm diameter aperture, 2 cm axial field-of-view ring-type research scanner seeks these goals by surrounding the animal with eighteen 15 mm deep, LGSO (7 mm)/GSO (8 mm) phoswich detector modules. A Monte Carlo simulation was used to compare the variation of resolution across the field-of-view and the absolute central point source sensitivity (ACS) of ATLAS to similar systems comprised only of LSO arrays of different depths with no depth-of-interaction (DOI) capability. For ATLAS radial spatial resolution deteriorated by 27% from the center to 3 cm off-axis. Scanners comprised of 15 mm deep, 10 mm deep and 7 mm deep LSO crystals deteriorated by 100%, 51%, and 20% respectively, over the same distance. Simulated ACS (absorbed energies /spl ges/250 keV) for ATLAS was 2.0% and for the 15 mm, 10 mm deep and 7 mm deep LSO scanners 2.4%, 1.5%, and 0.9%, respectively. Radial resolution loss 3 cm off-axis and ACS measured for the actual ATLAS scanner were similar to the values obtained by simulation (27% resolution loss, 1.8% ACS). The phoswich design thus achieves good resolution uniformity over a 6 cm FOV while preserving sensitivity compared to equivalent non-DOI LSO scanners with a range of crystal depths.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
NIH ATLAS小动物PET扫描仪的分辨率均匀性和灵敏度:与无深度交互能力的模拟LSO扫描仪的比较
设计用于对大鼠和小鼠大小的动物进行成像的PET扫描仪应同时具有高而均匀的空间分辨率和高灵敏度。ATLAS(先进技术实验室动物扫描仪)是一种直径11.8厘米、轴向2厘米的环形研究扫描仪,通过在动物周围放置18个15毫米深的LGSO(7毫米)/GSO(8毫米)光子探测器模块来寻找这些目标。采用蒙特卡罗模拟方法比较了ATLAS在视场范围内分辨率的变化,以及ATLAS对类似系统的绝对中心点源灵敏度(ACS),这些系统仅由不同深度的无交互深度(DOI)能力的LSO阵列组成。ATLAS的径向空间分辨率从中心到离轴3cm处下降了27%。在相同的距离内,由15mm深、10mm深和7mm深的LSO晶体组成的扫描仪分别损坏了100%、51%和20%。ATLAS的模拟ACS(吸收能量/spl ges/250 keV)为2.0%,15mm、10mm和7mm深LSO扫描仪的模拟ACS分别为2.4%、1.5%和0.9%。实际ATLAS扫描仪测得的离轴3 cm径向分辨率损失和ACS值与模拟所得值相似(分辨率损失27%,ACS值1.8%)。因此,与具有晶体深度范围的等效非doi LSO扫描仪相比,光导电路设计在6厘米视场内实现了良好的分辨率均匀性,同时保持了灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of IEC and IEEE standards for computer-based control systems important to safety Helicity-correlated systematics for SLAC Experiment E158 Achievements of the ASTRO-E Hard X-ray Detector development Inexpensive position sensitive detector block for 40 mm diameter PMT using quadrant sharing configuration A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1