{"title":"Automating motor-operated air-breaker switches","authors":"M. Eissa","doi":"10.1109/67.993761","DOIUrl":null,"url":null,"abstract":"The detection and clearing of transformer faults are intimately connected to the primary switching that is available. Breakers are used both as locations for the current transformers to detect a fault and define the zone of protection and as a way of clearing the fault. The use of so many circuit breakers (CB) is usually not justified economically. As an alternative, motor-operated air-breaker switches (MOAB) instead of CBs are commonly used. A MOAB cannot interrupt a fault and usually can be opened only if the adjacent transmission line segment is de-energized. The growth and increased complexity of power system configurations has led to arrangements of MOABs with transformers and power transmission lines. This causes a difficult situation when relay engineers coordinate operation of relay sequence and MOABs. This article presents a solution for such a difficulty. The solution utilizes a local area supervisory protection (LASP) system to collect voltage and current data and then share data among the associated relays.","PeriodicalId":435675,"journal":{"name":"IEEE Computer Applications in Power","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Computer Applications in Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/67.993761","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The detection and clearing of transformer faults are intimately connected to the primary switching that is available. Breakers are used both as locations for the current transformers to detect a fault and define the zone of protection and as a way of clearing the fault. The use of so many circuit breakers (CB) is usually not justified economically. As an alternative, motor-operated air-breaker switches (MOAB) instead of CBs are commonly used. A MOAB cannot interrupt a fault and usually can be opened only if the adjacent transmission line segment is de-energized. The growth and increased complexity of power system configurations has led to arrangements of MOABs with transformers and power transmission lines. This causes a difficult situation when relay engineers coordinate operation of relay sequence and MOABs. This article presents a solution for such a difficulty. The solution utilizes a local area supervisory protection (LASP) system to collect voltage and current data and then share data among the associated relays.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自动电机操作空气断路器开关
变压器故障的检测和清除与可用的一次开关密切相关。断路器既可用作电流互感器检测故障和确定保护区域的位置,也可用作清除故障的一种方式。使用这么多断路器(CB)通常是不合理的经济。作为替代方案,通常使用电机操作的空气断路器开关(MOAB)代替CBs。MOAB不能中断故障,通常只有在相邻的传输线段断电时才能打开。电力系统配置的增长和复杂性的增加导致了moab与变压器和输电线路的安排。这给继电工程师协调继电序列和moab的操作带来了困难。本文提出了解决这一难题的方法。该解决方案利用局部区域监督保护(LASP)系统收集电压和电流数据,然后在相关继电器之间共享数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimal linear control in stabilizer design Simulation and transient testing of numerical relays Deriving model parameters from field test measurements Prospective on computer applications in power Power electronics spark new simulation challenges
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1