Wrist cuff method determines mean arterial pressure in dual-cuff blood pressure system

J. Jílek, M. Stork
{"title":"Wrist cuff method determines mean arterial pressure in dual-cuff blood pressure system","authors":"J. Jílek, M. Stork","doi":"10.1109/AE.2014.7011687","DOIUrl":null,"url":null,"abstract":"Mean arterial pressure (MAP) is the pressure in the arteries averaged over time. Oscillometric blood pressure (BP) monitors determine the value of MAP by processing arterial pulses in the cuff. Cuff pressure at the point of largest pulse amplitude is equal to MAP. The oscillometric determination of MAP is subject to errors resulting from wave reflections and stroke volume variability. We developed an experimental system that uses two cuffs in order to improve accuracy of noninvasive BP measurement. The system consists of a compact module with pneumatic and electronic circuits, two detachable cuffs (arm and wrist), and a notebook computer connected to the module via a USB cable. This study concentrated on improvements in the determination of MAP using the wrist cuff pulses. The smallest wrist cuff amplitude in the middle segment of BP test was determined as the point of MAP. The corresponding arm cuff pressure was the value of MAP. Waveforms and cuff pressures from 40 BP tests were used to determine oscillometric, wrist cuff, and calculated MAP values and the values were compared. The results indicated that it is possible to determine MAP from wrist cuff pulse amplitudes and that the wrist cuff method may be more accurate than the oscillometric method.","PeriodicalId":149779,"journal":{"name":"2014 International Conference on Applied Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Applied Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AE.2014.7011687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Mean arterial pressure (MAP) is the pressure in the arteries averaged over time. Oscillometric blood pressure (BP) monitors determine the value of MAP by processing arterial pulses in the cuff. Cuff pressure at the point of largest pulse amplitude is equal to MAP. The oscillometric determination of MAP is subject to errors resulting from wave reflections and stroke volume variability. We developed an experimental system that uses two cuffs in order to improve accuracy of noninvasive BP measurement. The system consists of a compact module with pneumatic and electronic circuits, two detachable cuffs (arm and wrist), and a notebook computer connected to the module via a USB cable. This study concentrated on improvements in the determination of MAP using the wrist cuff pulses. The smallest wrist cuff amplitude in the middle segment of BP test was determined as the point of MAP. The corresponding arm cuff pressure was the value of MAP. Waveforms and cuff pressures from 40 BP tests were used to determine oscillometric, wrist cuff, and calculated MAP values and the values were compared. The results indicated that it is possible to determine MAP from wrist cuff pulse amplitudes and that the wrist cuff method may be more accurate than the oscillometric method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在双袖带血压系统中,腕带法测定平均动脉压
平均动脉压(MAP)是动脉压力随时间的平均值。示波血压(BP)监测仪通过处理袖带中的动脉脉冲来确定MAP的值。最大脉冲幅值点的袖带压力等于MAP。MAP的振荡测定受到由波反射和冲程体积变化引起的误差的影响。为了提高无创血压测量的准确性,我们开发了一种使用两个袖口的实验系统。该系统包括一个带有气动和电子电路的紧凑模块,两个可拆卸的袖口(手臂和手腕),以及一台通过USB电缆连接到该模块的笔记本电脑。本研究集中于改进使用腕带脉冲测定MAP的方法。取血压试验中段腕带振幅最小的点作为MAP点。相应的臂袖压力为MAP值。使用40 BP测试的波形和袖带压力来确定振荡、腕带和计算的MAP值,并对这些值进行比较。结果表明,从腕带的脉冲幅度可以确定MAP,并且腕带法可能比示波法更准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3D FEM simulation of small stripline for EMC testing Effect of dead times on the values of input current harmonics drawn from the grid by a voltage-source active rectifier Desktop based real time oxygen auto-ventilation and gas monitoring system for homecare respiratory application Fuzzy expert system for determining the human gait phase Dead-time compensation strategy with adaptive harmonic compensator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1