A nonlinear optimization tool for the full-bridge zero-voltage-switched DC-DC converter

A. Lotfi, Q. Chen, F. Lee
{"title":"A nonlinear optimization tool for the full-bridge zero-voltage-switched DC-DC converter","authors":"A. Lotfi, Q. Chen, F. Lee","doi":"10.1109/PESC.1992.254726","DOIUrl":null,"url":null,"abstract":"The fundamental equations characterizing the full-bridge zero-voltage-switched (ZVS) DC-DC power converter are utilized in a nonlinear design optimization routine. The design is subject to realistic constraints along with an objective function of minimal total volume and/or maximum efficiency. The routine is used to study the effects of switching frequency, leakage inductance and load range for ZVS on the efficiency and size. Maximum efficiency is shown to occur when ZVS is maintained in the immediate vicinity of full load operation. Experimental measurements confirm computed predictions.<<ETX>>","PeriodicalId":402706,"journal":{"name":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1992.254726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

Abstract

The fundamental equations characterizing the full-bridge zero-voltage-switched (ZVS) DC-DC power converter are utilized in a nonlinear design optimization routine. The design is subject to realistic constraints along with an objective function of minimal total volume and/or maximum efficiency. The routine is used to study the effects of switching frequency, leakage inductance and load range for ZVS on the efficiency and size. Maximum efficiency is shown to occur when ZVS is maintained in the immediate vicinity of full load operation. Experimental measurements confirm computed predictions.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全桥零电压开关DC-DC变换器的非线性优化工具
利用全桥零电压开关(ZVS) DC-DC功率变换器的基本方程进行非线性优化设计。设计受到现实的约束,以及最小的总体积和/或最大的效率的目标函数。应用程序研究了开关频率、漏感和负载范围对ZVS效率和尺寸的影响。当ZVS保持在满负荷运行附近时,显示出最大的效率。实验测量证实了计算的预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wiring for aerospace applications A complete transformer electric model, including frequency and geometry effects A general computer algorithm for analysis of switching converters Application of transmission line principles to high frequency power converters A simple and robust adaptive controller for PM motor robotic drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1