Self-Vibration Analysis of the Free-Fall Absolute Gravimeter

Zhenxing Li, K. Wu, Yi Wen, Jiamin Yao, Meiying Guo, Lijun Wang
{"title":"Self-Vibration Analysis of the Free-Fall Absolute Gravimeter","authors":"Zhenxing Li, K. Wu, Yi Wen, Jiamin Yao, Meiying Guo, Lijun Wang","doi":"10.1115/imece2019-10836","DOIUrl":null,"url":null,"abstract":"\n The ballistic free-fall absolute gravimeters are widely used in acquiring information of gravity field and the self-vibration of the absolute gravimeter is crucial for high precision gravitational measurement. The self-vibration of the T-1 absolute gravimeter has a multi-directional full-band excitation. The resulted horizontal swing has the major impact, since the T-1 absolute gravimeter is simplified as a cantilever beam. A laser vibrometer was applied to directly measure the mechanical self-vibration. The frequency of self-vibration has a nonlinear effect on the measurement error of g, and the peak frequencies should be avoided. The vibration signal was analyzed in time and frequency domain by continuous wavelet transform (CWT). The close frequency profiles were measured in the scalogram and the beat vibrations were observed in time domain as the results of the horizontal swing. The 38 Hz self-vibration had the dominating effect on the measurement error of g for T-1 absolute gravimeter. After optimizing the structure of the tripod, the dominating frequency increased from 38 Hz to 42 Hz. A 11% increase of the vibration frequency can reduce the measurement error of g.","PeriodicalId":197121,"journal":{"name":"Volume 11: Acoustics, Vibration, and Phononics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 11: Acoustics, Vibration, and Phononics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2019-10836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The ballistic free-fall absolute gravimeters are widely used in acquiring information of gravity field and the self-vibration of the absolute gravimeter is crucial for high precision gravitational measurement. The self-vibration of the T-1 absolute gravimeter has a multi-directional full-band excitation. The resulted horizontal swing has the major impact, since the T-1 absolute gravimeter is simplified as a cantilever beam. A laser vibrometer was applied to directly measure the mechanical self-vibration. The frequency of self-vibration has a nonlinear effect on the measurement error of g, and the peak frequencies should be avoided. The vibration signal was analyzed in time and frequency domain by continuous wavelet transform (CWT). The close frequency profiles were measured in the scalogram and the beat vibrations were observed in time domain as the results of the horizontal swing. The 38 Hz self-vibration had the dominating effect on the measurement error of g for T-1 absolute gravimeter. After optimizing the structure of the tripod, the dominating frequency increased from 38 Hz to 42 Hz. A 11% increase of the vibration frequency can reduce the measurement error of g.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自由落体绝对重力仪的自振动分析
弹道自由落体绝对重力仪在获取重力场信息方面有着广泛的应用,而绝对重力仪的自振动是实现高精度重力测量的关键。T-1绝对重力仪的自振动具有多向全波段激励。由于T-1绝对重力仪被简化为悬臂梁,因此产生的水平摆动具有主要影响。采用激光测振仪直接测量机械自振。自振动频率对测量误差g有非线性影响,应避免出现峰值频率。利用连续小波变换(CWT)对振动信号进行时域和频域分析。在尺度图上测量了紧密的频率分布,并在时域上观察了作为水平摆动结果的节拍振动。T-1型绝对重力仪的测量误差主要受38 Hz自振动的影响。优化三脚架结构后,主导频率由38 Hz提高到42 Hz。振动频率提高11%可减小g的测量误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Vibration Absorption in a Nonlinear Metamaterial Beam Incorporating Shape Memory Alloys Mechanical Design and Development of a Payload for Structural Health Monitoring Experiments on the International Space Station Ultrasonic Characterization of the Elastic Constants in an Aging Ti-6Al-4V ELI Alloy An Experimental Approach in Defect Detection of a Single Row Ball Bearing Using Noise Generation Signal Development and Design of the Dynamic Vibration Absorber Using Magneto-Rheological Elastomer for the Weight and Power Consumption Saving
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1