Optical fiber Fabry-Perot acoustic sensor based on large PDMS diaphragm

Han Zhou, Bingkun Wu, Mingguang Shan, Lei Liu, Haichao Yu, Z. Zhong, Bin Liu
{"title":"Optical fiber Fabry-Perot acoustic sensor based on large PDMS diaphragm","authors":"Han Zhou, Bingkun Wu, Mingguang Shan, Lei Liu, Haichao Yu, Z. Zhong, Bin Liu","doi":"10.1117/12.2511691","DOIUrl":null,"url":null,"abstract":"An extrinsic Fabry-Perot interferometric fibre microphone based on polydimethylsiloxane, or PDMS, diaphragm was proposed. The large free-standing PDMS diaphragm, with a diameter of 4 mm, is prepared by a simple “spin-strip” process. The experimental result shows that the fabricated sensor has a high dynamic pressure sensitivity of about -136 dB re 1 rad/μPa in the range of 100~2000Hz. The noise equivalent acoustic signal level of the microphone, limited by the environmental noise, is about 1000 μPa/Hz1/2. And the dynamic range is tested to be more than 47.48 dB. The proposed microphone is expected to be used in the field of weak acoustic pressure testing.","PeriodicalId":115119,"journal":{"name":"International Symposium on Precision Engineering Measurement and Instrumentation","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Precision Engineering Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2511691","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

An extrinsic Fabry-Perot interferometric fibre microphone based on polydimethylsiloxane, or PDMS, diaphragm was proposed. The large free-standing PDMS diaphragm, with a diameter of 4 mm, is prepared by a simple “spin-strip” process. The experimental result shows that the fabricated sensor has a high dynamic pressure sensitivity of about -136 dB re 1 rad/μPa in the range of 100~2000Hz. The noise equivalent acoustic signal level of the microphone, limited by the environmental noise, is about 1000 μPa/Hz1/2. And the dynamic range is tested to be more than 47.48 dB. The proposed microphone is expected to be used in the field of weak acoustic pressure testing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于大PDMS膜片的光纤法布里-珀罗声传感器
提出了一种基于聚二甲基硅氧烷(PDMS)膜片的外源法布里-珀罗干涉型光纤传声器。直径为4毫米的大型独立式PDMS膜片是通过简单的“旋带”工艺制备的。实验结果表明,该传感器在100~2000Hz范围内具有较高的动压灵敏度,约为-136 dB re 1 rad/μPa。受环境噪声限制,传声器的噪声等效声信号电平约为1000 μPa/Hz1/2。经测试,动态范围大于47.48 dB。该麦克风有望应用于弱声压测试领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel two-dimensional inductive sensor based on planar coils Combining compound eyes and human eye: a hybrid bionic imaging method for FOV extension and foveated vision Measurement of deionized water density based on single silicon sphere Research of variable-frequency big current calibration The optimization of segment’s axial support point for large astronomical telescopes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1