Quality-driven wavelet based PCG signal coding for wireless cardiac patient monitoring

M. Manikandan, K. P. Soman, S. Dandapat
{"title":"Quality-driven wavelet based PCG signal coding for wireless cardiac patient monitoring","authors":"M. Manikandan, K. P. Soman, S. Dandapat","doi":"10.1145/2185216.2185346","DOIUrl":null,"url":null,"abstract":"In this paper, we present a quality driven PCG signal coding scheme for wireless cardiac patient monitoring applications. The proposed quality driven codec is designed based on the wavelet-based compression method and the wavelet energy based diagnostic distortion (WEDD) measurement criterion. The proposed WEDD measure is the weighted percentage root mean square difference between the wavelet subband coefficients of the original and compressed signals with weights equal to the relative wavelet subband energies of the corresponding subbands. The WEDD measure appears to be a correct representation of the amount of signal distortion at all the subbands, and robust to insignificant errors in some bands. The performance of the proposed method is validated using the PCG signal blocks taken from the qdheart database and CAHM database PCG records which include many different valvular pathologies such as normal sounds, late systolic, ejection click, tricuspid regurgitation, diastolic aortic insufficiency, murmurs, and noises. Results showed that the performance of the WEDD criterion outperforms the PRDw and WWPRD criteria. For WEDD=4%, the maximum compression ratio of 186.07 was achieved for the test signal from the Diastolic Fixed S2 Split II record and the minimum compression ratio of 21.16 is obtained for the signal from the Diastolic Atrial Septal Defect record.","PeriodicalId":180836,"journal":{"name":"International Conference on Wireless Technologies for Humanitarian Relief","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Wireless Technologies for Humanitarian Relief","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2185216.2185346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

In this paper, we present a quality driven PCG signal coding scheme for wireless cardiac patient monitoring applications. The proposed quality driven codec is designed based on the wavelet-based compression method and the wavelet energy based diagnostic distortion (WEDD) measurement criterion. The proposed WEDD measure is the weighted percentage root mean square difference between the wavelet subband coefficients of the original and compressed signals with weights equal to the relative wavelet subband energies of the corresponding subbands. The WEDD measure appears to be a correct representation of the amount of signal distortion at all the subbands, and robust to insignificant errors in some bands. The performance of the proposed method is validated using the PCG signal blocks taken from the qdheart database and CAHM database PCG records which include many different valvular pathologies such as normal sounds, late systolic, ejection click, tricuspid regurgitation, diastolic aortic insufficiency, murmurs, and noises. Results showed that the performance of the WEDD criterion outperforms the PRDw and WWPRD criteria. For WEDD=4%, the maximum compression ratio of 186.07 was achieved for the test signal from the Diastolic Fixed S2 Split II record and the minimum compression ratio of 21.16 is obtained for the signal from the Diastolic Atrial Septal Defect record.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于质量驱动小波的心电监护信号编码
在本文中,我们提出了一种质量驱动的PCG信号编码方案,用于无线心脏患者监测。基于小波压缩方法和基于小波能量的诊断失真(WEDD)测量准则,设计了质量驱动编解码器。所提出的WEDD度量是原始信号和压缩信号的小波子带系数之差的加权百分比均方根,其权重等于相应子带的相对小波子带能量。WEDD测量似乎是所有子波段信号失真量的正确表示,并且对某些波段的不显著误差具有鲁棒性。采用来自qdheart数据库和CAHM数据库的PCG信号块来验证该方法的性能,这些PCG记录包括许多不同的瓣膜病理,如正常声音、收缩期晚期、射血咔嗒声、三尖瓣反流、舒张期主动脉不全、杂音和噪声。结果表明,WEDD准则的性能优于PRDw和WWPRD准则。当WEDD=4%时,舒张期Fixed S2 Split II记录检测信号的最大压缩比为186.07,舒张期房间隔缺损记录信号的最小压缩比为21.16。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A simultaneous routing and localization algorithm for wireless sensor networks in emergency scenario Monitoring Schumann resonance and other electromagnetic precursors of an earthquake with a virtual MIMO wireless sensor network Some comments on wireless sensor networks for natural hazards KARSHIK: agricultural information monitoring and reference based on wireless networks Robust RF fingerprinting techniques in 4G networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1