{"title":"Ultra-Low Resonance Frequency Mems Gravimeter with Off-Resonance Closed-Loop Control","authors":"C. Yi, Jun Wu, H. Maekoba, A. Parent, T. Ikehashi","doi":"10.1109/INERTIAL53425.2022.9787739","DOIUrl":null,"url":null,"abstract":"This paper reports on a MEMS gravimeter that has a closed-loop system to maintain an ultra-low resonance frequency of 1Hz. The low resonance frequency is attained by using a spring that is the resultant of positive mechanical stiffnesses and negative electrical stiffnesses. Voltage-tunability of the electrical stiffness enables ultra-small and tunable total stiffness. To attain a quick response even at the low resonance frequency, an amplitude monitoring and tuning are done at a higher off-resonance frequency of 330Hz. We demonstrate through simulations that the temperature dependence of the resonance frequency can be eliminated by using closed-loop tuning. To prevent issues caused by the ultra-small stiffness, we employ a force-balanced system that nulls the mass displacement. The sensitivity of the gravimeter is found to be 57V/Gal.","PeriodicalId":435781,"journal":{"name":"2022 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INERTIAL53425.2022.9787739","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper reports on a MEMS gravimeter that has a closed-loop system to maintain an ultra-low resonance frequency of 1Hz. The low resonance frequency is attained by using a spring that is the resultant of positive mechanical stiffnesses and negative electrical stiffnesses. Voltage-tunability of the electrical stiffness enables ultra-small and tunable total stiffness. To attain a quick response even at the low resonance frequency, an amplitude monitoring and tuning are done at a higher off-resonance frequency of 330Hz. We demonstrate through simulations that the temperature dependence of the resonance frequency can be eliminated by using closed-loop tuning. To prevent issues caused by the ultra-small stiffness, we employ a force-balanced system that nulls the mass displacement. The sensitivity of the gravimeter is found to be 57V/Gal.