Ganesh Prasad Khuntia, Ritesh Dash, Sarat Chandra Swain, P. Roy, Pramod Kumar Baghmar, Riya Paul
{"title":"Power Quality Analysis of Wind Generator under Symmetrical Fault Condition","authors":"Ganesh Prasad Khuntia, Ritesh Dash, Sarat Chandra Swain, P. Roy, Pramod Kumar Baghmar, Riya Paul","doi":"10.1109/i-PACT44901.2019.8960056","DOIUrl":null,"url":null,"abstract":"The increase in the capacity of wind turbines and development has achieved a remarkable high during the last decade. The grid connected wind farm must able to provide quality power and as well as grid reliability must be maintained with new regulations and grid code. It is a general practice to study the power quality of grid connected wind farm system along with its disturbance and how it affects the grid to which it is connected. In this paper a comparative analysis of different wind farms and their grid connected activities along with PI- linear controller has been demonstrated. A comparative analysis of wind turbine performance has been demonstrated in this paper. Matlab Simulink model has been used for modelling of the system and study the performance of system under grid disturbances.","PeriodicalId":214890,"journal":{"name":"2019 Innovations in Power and Advanced Computing Technologies (i-PACT)","volume":"14 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Innovations in Power and Advanced Computing Technologies (i-PACT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/i-PACT44901.2019.8960056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The increase in the capacity of wind turbines and development has achieved a remarkable high during the last decade. The grid connected wind farm must able to provide quality power and as well as grid reliability must be maintained with new regulations and grid code. It is a general practice to study the power quality of grid connected wind farm system along with its disturbance and how it affects the grid to which it is connected. In this paper a comparative analysis of different wind farms and their grid connected activities along with PI- linear controller has been demonstrated. A comparative analysis of wind turbine performance has been demonstrated in this paper. Matlab Simulink model has been used for modelling of the system and study the performance of system under grid disturbances.