Synchronization in the image Flow Cytometer

F. Lamonaca, D. Grimaldi, A. Nastro
{"title":"Synchronization in the image Flow Cytometer","authors":"F. Lamonaca, D. Grimaldi, A. Nastro","doi":"10.1109/IDAACS.2011.6072805","DOIUrl":null,"url":null,"abstract":"The Image Flow-Cytometer permits to acquire the cell images of the lymphocytes. These images are used to count the Micro Nucleuses (MNs) induced in the cells by carcinogenic agents. The result of the count is widely used for analysis of cytogenetic damage. The acquisition is performed under the hypothesis of laminar flow of the lymphocyte. Nevertheless, many are the causes that make invalid this hypothesis and cause alterations during the image acquisition. The final effect is the presence of different alterations superimposed to the images, that misstate the algorithms used to detect the MNs. In order to reduce the number of images affected by not admissible alteration range, and to increase the reliability of the medical response, a new hardware system is pointed out to synchronize with high accuracy the image acquisition to the lymphocyte flow.","PeriodicalId":106306,"journal":{"name":"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IDAACS.2011.6072805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Image Flow-Cytometer permits to acquire the cell images of the lymphocytes. These images are used to count the Micro Nucleuses (MNs) induced in the cells by carcinogenic agents. The result of the count is widely used for analysis of cytogenetic damage. The acquisition is performed under the hypothesis of laminar flow of the lymphocyte. Nevertheless, many are the causes that make invalid this hypothesis and cause alterations during the image acquisition. The final effect is the presence of different alterations superimposed to the images, that misstate the algorithms used to detect the MNs. In order to reduce the number of images affected by not admissible alteration range, and to increase the reliability of the medical response, a new hardware system is pointed out to synchronize with high accuracy the image acquisition to the lymphocyte flow.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
流式细胞仪图像同步
图像流式细胞仪可以获得淋巴细胞的细胞图像。这些图像用于计算由致癌物在细胞中诱导的微核(MNs)。该计数结果被广泛用于细胞遗传学损伤的分析。采集是在淋巴细胞层流的假设下进行的。然而,许多原因使这一假设无效,并导致图像采集过程中的变化。最终的效果是叠加在图像上的不同变化,错误地描述了用于检测MNs的算法。为了减少受不可接受变化范围影响的图像数量,提高医疗响应的可靠性,提出了一种新的硬件系统,使图像采集与淋巴细胞流动高精度同步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automated measurement system based on digital intertial sensors for the study of human body movement Assessment of probabilistic parameters of alarm security detectors taking uncertain noise into account Special areas detection on agricultural fields images using evaluations of local brightness variability Net Present Value (NPV) as a tool supporting effective project management Photoplethysmography detection by smartphone's videocamera
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1