M. Vratonjic, A. Rahmatmand, Feras Marish, P. Sullivan
{"title":"Model of a System-Wide Domestic Hot-Water Distribution System in a Multi-Resident High-Rise Building","authors":"M. Vratonjic, A. Rahmatmand, Feras Marish, P. Sullivan","doi":"10.1115/1.4049799","DOIUrl":null,"url":null,"abstract":"\n To reduce the environmental impact and cost, energy and water consumption of multi-resident buildings should be improved while ensuring resident comfort. Inefficient mixing of hot and cold-water streams and a non-optimal domestic hot-water (DHW) distribution system design can cause higher energy consumption, component failures, and dissatisfied residents. An OpenModelica (OM) system-wide model of a 14-story building consisting of a controlled-loop injection (CLI) device and a DHW distribution system is presented. The OM results are validated against field measurements at discreet locations within a single-zone closed-loop circuit to ensure the validity of time-varying temperature and flowrate. The study demonstrates that OM is a useful engineering tool to model single and multi-zone high-rise buildings that allows advanced analysis, including system-wide optimization, advanced on-demand controls, and energy and water-usage efficiencies.","PeriodicalId":326594,"journal":{"name":"ASME Journal of Engineering for Sustainable Buildings and Cities","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME Journal of Engineering for Sustainable Buildings and Cities","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4049799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
To reduce the environmental impact and cost, energy and water consumption of multi-resident buildings should be improved while ensuring resident comfort. Inefficient mixing of hot and cold-water streams and a non-optimal domestic hot-water (DHW) distribution system design can cause higher energy consumption, component failures, and dissatisfied residents. An OpenModelica (OM) system-wide model of a 14-story building consisting of a controlled-loop injection (CLI) device and a DHW distribution system is presented. The OM results are validated against field measurements at discreet locations within a single-zone closed-loop circuit to ensure the validity of time-varying temperature and flowrate. The study demonstrates that OM is a useful engineering tool to model single and multi-zone high-rise buildings that allows advanced analysis, including system-wide optimization, advanced on-demand controls, and energy and water-usage efficiencies.