Methods for Reducing Energy Consumption, Optimization in Operational Data Centers

C. Dumitrescu, A. Plesca, M. Adam, Costică Nițucă, A. Dragomir
{"title":"Methods for Reducing Energy Consumption, Optimization in Operational Data Centers","authors":"C. Dumitrescu, A. Plesca, M. Adam, Costică Nițucă, A. Dragomir","doi":"10.1109/ICEPE.2018.8559920","DOIUrl":null,"url":null,"abstract":"This paper proposes a methods to reduce energy consumption in an operational data center facility. Data centers are the places where Information Technology and Communications equipment are hosted. From the day when the first computer was developed, the room that houses the mainframe faced with challenges regarding power and cooling requested, redundancy and availability for the systems to avoid any interruption, also with capacity planning for future expansions. All back-up and hot stand-by system are more often over-sized the focus are on availability nor on efficiency. The Information and Communication Technology (ICT) evolution, the need to compute and store more information lead to exponential increase of ICT equipment. The technology evolution lead to changes of equipment hosted in Data Centers with more performant systems but with high density of energy consumed. The virtualization of services is a way to increase computing performance with increasing utilization load of processors. Overall IT systems providing, the same functionality more efficient, consuming less power. Usually the evolution of ICT infrastructure (consolidation) is not correlated with facility changes that will impact the performance of existing data center. Increasing the power density in an operational computer room will produce a major impact to cooling system capacity and efficiency. The challenge is to avoid overheat areas (hot spots) and to provide same environment condition without changing the space geometry or design, increasing the efficiency and optimize energy consumption.","PeriodicalId":343896,"journal":{"name":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE.2018.8559920","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper proposes a methods to reduce energy consumption in an operational data center facility. Data centers are the places where Information Technology and Communications equipment are hosted. From the day when the first computer was developed, the room that houses the mainframe faced with challenges regarding power and cooling requested, redundancy and availability for the systems to avoid any interruption, also with capacity planning for future expansions. All back-up and hot stand-by system are more often over-sized the focus are on availability nor on efficiency. The Information and Communication Technology (ICT) evolution, the need to compute and store more information lead to exponential increase of ICT equipment. The technology evolution lead to changes of equipment hosted in Data Centers with more performant systems but with high density of energy consumed. The virtualization of services is a way to increase computing performance with increasing utilization load of processors. Overall IT systems providing, the same functionality more efficient, consuming less power. Usually the evolution of ICT infrastructure (consolidation) is not correlated with facility changes that will impact the performance of existing data center. Increasing the power density in an operational computer room will produce a major impact to cooling system capacity and efficiency. The challenge is to avoid overheat areas (hot spots) and to provide same environment condition without changing the space geometry or design, increasing the efficiency and optimize energy consumption.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
运营数据中心降低能耗、优化的方法
本文提出了一种降低运营数据中心设施能耗的方法。数据中心是承载信息技术和通信设备的地方。从第一台计算机开发的那一天起,容纳主机的房间就面临着各种挑战,包括电源和冷却要求、系统冗余和可用性以避免任何中断,以及未来扩展的容量规划。所有的备用和热备用系统通常都是超大的,重点是可用性而不是效率。随着信息通信技术(ICT)的发展,计算和存储更多信息的需求导致ICT设备呈指数级增长。随着技术的发展,数据中心内的设备也发生了变化,系统性能越来越高,但能耗也越来越高。服务虚拟化是一种通过增加处理器的利用率负载来提高计算性能的方法。整体IT系统提供相同的功能,效率更高,功耗更低。通常,ICT基础设施的发展(整合)与影响现有数据中心性能的设施变化无关。提高计算机机房的功率密度将对冷却系统的容量和效率产生重大影响。挑战在于避免过热区域(热点),并在不改变空间几何形状或设计的情况下提供相同的环境条件,提高效率并优化能耗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Emotion Analysis Architecture Based on Face and Physiological Sensing Applied with Flight Simulator Analysis of Light Design in the Lighting Laboratory of the Riga Technical University Morphological, Physiological and Productive Indicators of Lettuce under Non-thermal Plasma Coherence and Continuity in the Continuing Education of Electrical and Energetic Field Teachers from the Pre-University Environment Solution to improve the quality of electricity in low voltage networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1