Nasrin Afsarimanesh, A. I. Zia, S. C. Mukhopadhyay, M. Kruger, P. Yu, J. Kosel
{"title":"Development of a sensing system to detect C-telopeptide of type-I collagen","authors":"Nasrin Afsarimanesh, A. I. Zia, S. C. Mukhopadhyay, M. Kruger, P. Yu, J. Kosel","doi":"10.1109/ICSENST.2015.7438466","DOIUrl":null,"url":null,"abstract":"This research work describes a non-invasive and label-free immunosensing technique to detect the C-telopeptide of type-I collagen (CTX-1) by Electrochemical Impedance Spectroscopy (EIS). A planar interdigital capacitive sensor is used to evaluate the properties of the material under test. This sensor was fabricated on the basis of thin film micro-electromechanical system (MEMS) semiconductor device fabrication technology. EIS was used in conjunction with the sensor to detect collagen type-I in blood plasma. At the first stage, the Serum CrossLaps® ELISA was used to measure some known samples in order to obtain a standard curve. Streptavidin agarose was successfully immobilized on the sensing area of the sensor. After that the experiments were done with antibody solution and three known samples of CTX-1, zero concentration which was considered as control, 2.669 ng/ml and 0.798 ng/ml concentration. The results are encouraging for further investigation.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2015.7438466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This research work describes a non-invasive and label-free immunosensing technique to detect the C-telopeptide of type-I collagen (CTX-1) by Electrochemical Impedance Spectroscopy (EIS). A planar interdigital capacitive sensor is used to evaluate the properties of the material under test. This sensor was fabricated on the basis of thin film micro-electromechanical system (MEMS) semiconductor device fabrication technology. EIS was used in conjunction with the sensor to detect collagen type-I in blood plasma. At the first stage, the Serum CrossLaps® ELISA was used to measure some known samples in order to obtain a standard curve. Streptavidin agarose was successfully immobilized on the sensing area of the sensor. After that the experiments were done with antibody solution and three known samples of CTX-1, zero concentration which was considered as control, 2.669 ng/ml and 0.798 ng/ml concentration. The results are encouraging for further investigation.