{"title":"An improved method of detecting contamination of HV stator windings in the field","authors":"C. Pinto","doi":"10.1109/EEIC.1991.162569","DOIUrl":null,"url":null,"abstract":"The preferred method of detecting contamination of stator winding insulation is to measure its DC resistance (IR) and polarization index (PI). However, a number of cases have been reported where good IR and PI values have been obtained despite the windings being considerably contaminated. While attempting to compute variations of the polarizing currents in the frequency domain, the author has made of the results obtained in conjunction with low-voltage AC measurements at the supply frequency to detect contaminations of the two windings. A method has been suggested that could help detect contamination in cases of the above-mentioned good IR and PI values by estimating tan delta and capacitance variations with frequency from the charging current curve and comparing the same with measured tan delta values.<<ETX>>","PeriodicalId":367238,"journal":{"name":"[1991] Proceedings of the 20th Electrical Electronics Insulation Conference","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 20th Electrical Electronics Insulation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.1991.162569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

The preferred method of detecting contamination of stator winding insulation is to measure its DC resistance (IR) and polarization index (PI). However, a number of cases have been reported where good IR and PI values have been obtained despite the windings being considerably contaminated. While attempting to compute variations of the polarizing currents in the frequency domain, the author has made of the results obtained in conjunction with low-voltage AC measurements at the supply frequency to detect contaminations of the two windings. A method has been suggested that could help detect contamination in cases of the above-mentioned good IR and PI values by estimating tan delta and capacitance variations with frequency from the charging current curve and comparing the same with measured tan delta values.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种改进的现场高压定子绕组污染检测方法
检测定子绕组绝缘污染的首选方法是测量其直流电阻(IR)和极化指数(PI)。然而,据报道,在一些情况下,尽管绕组受到严重污染,但仍获得了良好的IR和PI值。在试图计算频域中极化电流的变化时,作者已将结果与电源频率下的低压交流测量相结合,以检测两个绕组的污染。在上述良好的IR和PI值的情况下,通过从充电电流曲线估计tan delta和电容随频率的变化,并将其与测量的tan delta值进行比较,提出了一种方法,可以帮助检测污染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advances in thermoplastic coil encapsulation Storage and decay of electrical charge in high temperature dielectrics JIT/TQC-identifying and solving problems Powdered epoxy resin test methods The effect of the Clean Air Act on the electrical/electronics industry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1