{"title":"Harmonic quality analysis of a low power static converter","authors":"F. López","doi":"10.1109/TDC-LA.2018.8511729","DOIUrl":null,"url":null,"abstract":"This paper establishes new technical aspects for the analysis of harmonic voltage for a low power static converter. With the contribution of an advanced energy analyzer, the harmonic content of a distorted wave have verified with the operation of a low power static converter. It proposes a schematic test circuit to verify the harmonics of voltage, evaluates the different types of harmonics that appear in the low power static converter, with and without electrical load, the first test with the purpose of verify the real sine wave ofvoltage that determining the manufacturer of electronic devices. While the second test with objective of determine the harmonic that appear with electric load interactions. It presents the voltage and current waves obtained from the measurements and finally to present some results obtained from a test electrical circuit with mitigation proposals to control harmonics.","PeriodicalId":267301,"journal":{"name":"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC-LA.2018.8511729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper establishes new technical aspects for the analysis of harmonic voltage for a low power static converter. With the contribution of an advanced energy analyzer, the harmonic content of a distorted wave have verified with the operation of a low power static converter. It proposes a schematic test circuit to verify the harmonics of voltage, evaluates the different types of harmonics that appear in the low power static converter, with and without electrical load, the first test with the purpose of verify the real sine wave ofvoltage that determining the manufacturer of electronic devices. While the second test with objective of determine the harmonic that appear with electric load interactions. It presents the voltage and current waves obtained from the measurements and finally to present some results obtained from a test electrical circuit with mitigation proposals to control harmonics.