{"title":"Analysis of Deformations and Von-Misses Stresses of the Main Shaft System in a Load Break Switch","authors":"Džanko Hajradinović, S. Santamaria, S. Delić, N. Uzelac, Maroua O Touhami, M. Kapetanović","doi":"10.2478/bhee-2021-0009","DOIUrl":null,"url":null,"abstract":"Abstract This paper presents the study of deformations and Von-Misses stresses of the main shaft system during opening and closing operations of a rotary SF6 load break switch (LBS). The shaft consists of three axially connected parts made of steel where components are on ground potential and of plastic material, which is on high potential. The insulating shaft carries three rotating knife-blade contacts for the three phases. Static deformation of the insulating shaft is calculated by applying a defined torque between the two ends of the shaft. The results allow deducing the dynamic deformation. Maximum values of Von-Misses stresses are located at the geared connection between the plastic and the steel shaft. The rotation of the shaft system is measured synchronously by two optical rotary encoders in the front and rear sides of the LBS. The results confirm the twisting of the shaft system and provide its elastic deformation values. Travel curves obtained on both side of the LBS show different courses with respect to overtravel and rebound. Discrepancies can be explained by the deformation of the main shaft due to the acting forces, whereas manufacturing tolerances resulting in loose have a certain contribution.","PeriodicalId":236883,"journal":{"name":"B&H Electrical Engineering","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"B&H Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/bhee-2021-0009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract This paper presents the study of deformations and Von-Misses stresses of the main shaft system during opening and closing operations of a rotary SF6 load break switch (LBS). The shaft consists of three axially connected parts made of steel where components are on ground potential and of plastic material, which is on high potential. The insulating shaft carries three rotating knife-blade contacts for the three phases. Static deformation of the insulating shaft is calculated by applying a defined torque between the two ends of the shaft. The results allow deducing the dynamic deformation. Maximum values of Von-Misses stresses are located at the geared connection between the plastic and the steel shaft. The rotation of the shaft system is measured synchronously by two optical rotary encoders in the front and rear sides of the LBS. The results confirm the twisting of the shaft system and provide its elastic deformation values. Travel curves obtained on both side of the LBS show different courses with respect to overtravel and rebound. Discrepancies can be explained by the deformation of the main shaft due to the acting forces, whereas manufacturing tolerances resulting in loose have a certain contribution.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
负载开关主轴系统变形及非失效应力分析
摘要:本文研究了SF6型旋转负荷开关(LBS)开合过程中主轴系统的变形和von - miss应力。轴由三个轴向连接的部件组成,其中钢部件为接地电位,塑料部件为高电位。绝缘轴为三相携带三个旋转刀片触点。绝缘轴的静态变形是通过在轴的两端施加一个确定的扭矩来计算的。计算结果可以推导出动态变形。von - miss应力的最大值位于塑料轴和钢轴之间的齿轮连接处。轴系的旋转由LBS前后两侧的两个光学旋转编码器同步测量。结果证实了轴系的扭态,并给出了其弹性变形值。在LBS两侧得到的行程曲线显示出不同的超行程和回弹路线。差异可以用主轴受力引起的变形来解释,而制造公差导致的松动也有一定的贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Increasing the Capacity of the Distribution Network by Changing Consumers’ Habits - Case Study Long-Range Remote Control Based on LoRa Transceivers Digital Transformation Path of Manually Collected Meter Reading Data Profile Optimisation in Real Distribution Networks (Case Study Long MV Feeder) New Functions of VSC Based HVDC Transmission Systems that Can Effectively Support the Future South-East European Grid with Low Inertia and Large Amount of Res Generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1