{"title":"Operation Region Selector Circuit to Obtain Maximum Efficiency of 250 W Boost Converter","authors":"R. R. O. Sasue, E. Firmansyah, S. Suharyanto","doi":"10.22146/IJITEE.36649","DOIUrl":null,"url":null,"abstract":"Interleaved boost converter gives good conversion efficiency due to its zero-current switching capability when operating in discontinuous conduction mode while keeping its input-output ripple current low. However, operating this kind of converter at interleaved operation for all the time gives poor efficiency under light-load condition. In this paper, an automatic operation region selector switch based on detection of the continuous or discontinuous current mode is proposed. With this switch, during the light-load condition, only one converter is activated, while during full-load condition both converters will be activated. The simulation results using LTspice software show that the proposed boost converter has a better efficiency compared to the conventional boost converter with efficiency range of 84.6 % to 95.32 % under various load conditions.","PeriodicalId":292390,"journal":{"name":"IJITEE (International Journal of Information Technology and Electrical Engineering)","volume":"174 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJITEE (International Journal of Information Technology and Electrical Engineering)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/IJITEE.36649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Interleaved boost converter gives good conversion efficiency due to its zero-current switching capability when operating in discontinuous conduction mode while keeping its input-output ripple current low. However, operating this kind of converter at interleaved operation for all the time gives poor efficiency under light-load condition. In this paper, an automatic operation region selector switch based on detection of the continuous or discontinuous current mode is proposed. With this switch, during the light-load condition, only one converter is activated, while during full-load condition both converters will be activated. The simulation results using LTspice software show that the proposed boost converter has a better efficiency compared to the conventional boost converter with efficiency range of 84.6 % to 95.32 % under various load conditions.