{"title":"Analysis of Strain-gage Records from a Static Loading Test on a CFA Pile","authors":"B. Fellenius","doi":"10.37308/dfijnl.20181008.189","DOIUrl":null,"url":null,"abstract":"A static test was performed on a 610-mm diameter, 10 m long CFA pile installed through 3 m of clay and sand and into a thick deposit of lacustrine clay. The loading procedure included prolonged load-holding and an unloading-reloading event, which adversely affected the interpretations of the strain records and demonstrated the inadvisability of not performing a test with equal load-increments and equal load-holding durations and avoiding all unloading-reloading sequences. The pile was strain-gage instrumented at three levels and the recorded strains were used to calculate the pile axial stiffness and determine the load distributions for the applied load. Back-calculations using effective stress analysis were fitted to strain-gage determined load distributions and were then used in simulating the measured pile-head load-movement of the test pile.","PeriodicalId":339795,"journal":{"name":"DFI Journal: The Journal of the Deep Foundations Institute","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DFI Journal: The Journal of the Deep Foundations Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37308/dfijnl.20181008.189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A static test was performed on a 610-mm diameter, 10 m long CFA pile installed through 3 m of clay and sand and into a thick deposit of lacustrine clay. The loading procedure included prolonged load-holding and an unloading-reloading event, which adversely affected the interpretations of the strain records and demonstrated the inadvisability of not performing a test with equal load-increments and equal load-holding durations and avoiding all unloading-reloading sequences. The pile was strain-gage instrumented at three levels and the recorded strains were used to calculate the pile axial stiffness and determine the load distributions for the applied load. Back-calculations using effective stress analysis were fitted to strain-gage determined load distributions and were then used in simulating the measured pile-head load-movement of the test pile.