Assessment and elimination of errors due to electrode displacements in elliptical and square models in EIT

A. Javaherian, A. Movafeghi, R. Faghihi
{"title":"Assessment and elimination of errors due to electrode displacements in elliptical and square models in EIT","authors":"A. Javaherian, A. Movafeghi, R. Faghihi","doi":"10.1109/IRANIANMVIP.2010.5941160","DOIUrl":null,"url":null,"abstract":"This study modifies a Tikhonov regularized \"maximum a posteriori\" algorithm proposed for reconstructing both the conductivity changes and electrode positioning variations in EIT and uses this algorithm for reconstructing images of 2d elliptical and square models, instead of simple circular model used in previous works. This algorithm had been proposed By C. Gomez for compensating the errors due to electrode movements in image reconstruction. The jacobian matrix has been constructed via perturbation both conductivity and electrode positioning. The prior image matrix should incorporate some kind of augmented inter-electrode positioning correlations to impose a smoothness constraint on both the conductivity change distribution and electrode movement. For each model, conductivity change image is reconstructed in 3 cases: a) With no electrode displacement using standard algorithm b) With electrode displacement using standard algorithm c) With electrode displacement using proposed algorithm. In all models, a comparison between 3 cases has been implemented. Also, the results obtained from each model have been compared with the other models in similar cases. The results obtained in this study will be useful to investigate the ellipticity effects of organs being imaged in clinical applications. Moreover, the effects of model deviation from circular form on reconstructed images can be used in special industrial applications.","PeriodicalId":350778,"journal":{"name":"2010 6th Iranian Conference on Machine Vision and Image Processing","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 6th Iranian Conference on Machine Vision and Image Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRANIANMVIP.2010.5941160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study modifies a Tikhonov regularized "maximum a posteriori" algorithm proposed for reconstructing both the conductivity changes and electrode positioning variations in EIT and uses this algorithm for reconstructing images of 2d elliptical and square models, instead of simple circular model used in previous works. This algorithm had been proposed By C. Gomez for compensating the errors due to electrode movements in image reconstruction. The jacobian matrix has been constructed via perturbation both conductivity and electrode positioning. The prior image matrix should incorporate some kind of augmented inter-electrode positioning correlations to impose a smoothness constraint on both the conductivity change distribution and electrode movement. For each model, conductivity change image is reconstructed in 3 cases: a) With no electrode displacement using standard algorithm b) With electrode displacement using standard algorithm c) With electrode displacement using proposed algorithm. In all models, a comparison between 3 cases has been implemented. Also, the results obtained from each model have been compared with the other models in similar cases. The results obtained in this study will be useful to investigate the ellipticity effects of organs being imaged in clinical applications. Moreover, the effects of model deviation from circular form on reconstructed images can be used in special industrial applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EIT中椭圆和方形模型中电极位移误差的评估与消除
本研究改进了Tikhonov正则化“最大后检”算法,用于重建电导率变化和电极定位变化,并将该算法用于重建二维椭圆和正方形模型的图像,而不是以往工作中使用的简单圆形模型。该算法由C. Gomez提出,用于补偿图像重建中电极运动引起的误差。通过对电导率和电极定位的摄动,构造了雅可比矩阵。先验图像矩阵应该包含某种增强的电极间定位相关性,以对电导率变化分布和电极运动施加平滑约束。对于每个模型,重构3种情况下的电导率变化图像:a)使用标准算法无电极位移b)使用标准算法有电极位移c)使用本文提出的算法有电极位移。在所有模型中,进行了3个案例的比较。并将各模型的计算结果与其他模型在类似情况下的计算结果进行了比较。本研究的结果将有助于在临床应用中探讨被成像器官的椭圆性效应。此外,模型偏离圆形对重建图像的影响可用于特殊工业应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Lung nodule segmentation using active contour modeling A new cumulant-based active contour model with wavelet energy for segmentation of SAR images Human action recognition by RANSAC based salient features of skeleton history image using ANFIS Automatic extraction of positive cells in pathology images of meningioma based on the maximal entropy principle and HSV color space Multiple description video coding based on Lagrangian rate allocation and JPEG2000
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1