On the influence of inclined lightning channel on lightning induced voltage evaluation

N. Rameli, M. Kadir, M. Izadi, Chandima Gomes, J. Jasni
{"title":"On the influence of inclined lightning channel on lightning induced voltage evaluation","authors":"N. Rameli, M. Kadir, M. Izadi, Chandima Gomes, J. Jasni","doi":"10.1109/ICLP.2012.6344250","DOIUrl":null,"url":null,"abstract":"This paper investigates the influence of inclined lightning channel on induced voltage on the line. The angle variations of inclined lightning channel may cause the voltage to be induced at different values for different points along the power line. This behaviour may affect the line's lightning performance if the peak of induced voltage is greater than the critical flashover voltage (CFO) of the line. This induced voltage is expected to be increased when the inclined angle with respect to the observation point is decreased. Appropriate method of induced voltage algorithm with respect to the incline lightning channel will be developed and compared with other method. The outcome of this study would be useful for the utility for their planning and selection of appropriate protection scheme for the line.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

This paper investigates the influence of inclined lightning channel on induced voltage on the line. The angle variations of inclined lightning channel may cause the voltage to be induced at different values for different points along the power line. This behaviour may affect the line's lightning performance if the peak of induced voltage is greater than the critical flashover voltage (CFO) of the line. This induced voltage is expected to be increased when the inclined angle with respect to the observation point is decreased. Appropriate method of induced voltage algorithm with respect to the incline lightning channel will be developed and compared with other method. The outcome of this study would be useful for the utility for their planning and selection of appropriate protection scheme for the line.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
倾斜闪电通道对雷电感应电压评估的影响
本文研究了倾斜雷电通道对线路感应电压的影响。倾斜雷击通道的角度变化可能导致沿电力线不同位置的感应电压值不同。如果感应电压的峰值大于线路的临界闪络电压(CFO),这种行为可能会影响线路的雷电性能。当相对于观测点的倾斜角度减小时,预计感应电压会增加。针对倾斜闪电通道,提出合适的感应电压算法,并与其他方法进行比较。本研究的结果将有助于电力公司规划和选择合适的线路保护方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Two unprecedented experiments to evaluate the effectiveness of lightning protection systems Investigations of earth termination systems with respect to optimised step voltages Estimation of the minimum shielding failure current causing flashover in overhead lines of the hellenic transmission system through ATP-EMTP simulations Calculating the Lightning Protection System downconductors' grounding resistance at Launch Complex 39B, Kennedy Space Center, Florida Factors influencing the selection and installation of surge protective devices for low voltage systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1