{"title":"Effect of rotational direction on the performance of a three-phase induction generator connected to a single-phase power system","authors":"T. Chan","doi":"10.1109/IEMDC.1997.604086","DOIUrl":null,"url":null,"abstract":"This paper analyzes the performance of a three-phase induction generator which is connected to a single-phase power system. Significant improvement in machine performance can be obtained by using a static phase-converter, provided that the machine is driven in the reverse direction. The theoretical analysis a validated by experiments on a 2 kW test machine.","PeriodicalId":176640,"journal":{"name":"1997 IEEE International Electric Machines and Drives Conference Record","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE International Electric Machines and Drives Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMDC.1997.604086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
This paper analyzes the performance of a three-phase induction generator which is connected to a single-phase power system. Significant improvement in machine performance can be obtained by using a static phase-converter, provided that the machine is driven in the reverse direction. The theoretical analysis a validated by experiments on a 2 kW test machine.