Relation between the weight of human tooth enamel and the CO3(3-) signal intensity on the ESR dosimetry.

Ou Daigaku shigakushi Pub Date : 1990-07-01
M Iwasaki, C Miyazawa, T Shimano
{"title":"Relation between the weight of human tooth enamel and the CO3(3-) signal intensity on the ESR dosimetry.","authors":"M Iwasaki,&nbsp;C Miyazawa,&nbsp;T Shimano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Experiments were made to determine the dependence of CO3(3-) signal intensity on enamel weight in the ESR dosimetry utilizing teeth. After all human tooth enamel samples were crushed into 500-840 micrometers particles, they were irradiated with various doses of 60Co gamma rays at the same dose rate. Irradiated samples were distributed into 10-500 milli-grams weights and were measured with ESR instrument. The relation between CO3(3-) signal intensity and enamel weight have linearity up to 300 mg weight under the same dose as shown by measurements.</p>","PeriodicalId":77585,"journal":{"name":"Ou Daigaku shigakushi","volume":"17 2","pages":"95-100"},"PeriodicalIF":0.0000,"publicationDate":"1990-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ou Daigaku shigakushi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Experiments were made to determine the dependence of CO3(3-) signal intensity on enamel weight in the ESR dosimetry utilizing teeth. After all human tooth enamel samples were crushed into 500-840 micrometers particles, they were irradiated with various doses of 60Co gamma rays at the same dose rate. Irradiated samples were distributed into 10-500 milli-grams weights and were measured with ESR instrument. The relation between CO3(3-) signal intensity and enamel weight have linearity up to 300 mg weight under the same dose as shown by measurements.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人牙釉质重量与ESR剂量学中CO3(3-)信号强度的关系。
实验研究了牙体ESR剂量法中CO3(3-)信号强度与牙釉质重量的关系。将所有人类牙釉质样品粉碎成500-840微米的颗粒后,以相同剂量率用不同剂量的60Co伽马射线照射。将辐照后的样品分成10 ~ 500毫克的重量,用ESR仪测量。测量结果表明,在相同剂量下,CO3(3-)信号强度与牙釉质重量呈线性关系,直至300 mg重量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[A problem with ESR dosimetry utilizing human tooth enamel in low dose region]. [A study on the application of Ga-As semiconductor laser to endodontics. The effects of laser irradiation on the activation of inflammatory cells and the vital pulpotomy]. [The clinico-pathological studies on the influence of immediate root canal filling after formalin guaiacol was applied on the extirpated pulp surface]. [Eccentric projection for the observation of the root canals of the upper premolars]. [Research of condylar movement on nonworking side during quantitative lateral movement of mandible].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1