Duha Yasser, Mohamed A. Elgamal, M. Atef, O. Hamada, Ali H. Hassan, H. Mostafa
{"title":"A comparative analysis of optimized low-power comparators for biomedical-ADCs","authors":"Duha Yasser, Mohamed A. Elgamal, M. Atef, O. Hamada, Ali H. Hassan, H. Mostafa","doi":"10.1109/ICM.2017.8268879","DOIUrl":null,"url":null,"abstract":"Comparators are essential blocks in implementing analog-to-digital converters (ADCs). An energy-efficient ADC such as successive approximation register (SAR) ADC or dual-slope ADC requires at least one comparator, where the power consumption mainly depends on the comparator design. This paper investigates various implementation techniques of low-power comparators emphasizing on their design performance metrics, and trade-offs such as sampling frequency, resolution, and power consumption. The proposed comparative analysis covers a recently published low power comparators for bio-signals monitoring and proposes a basic optimization method for these comparators. These comparators are redesigned using UMC 130nm CMOS technology for a fair comparison to present a good reference for proper choosing of a low power comparator that serves low-power bio-medical applications.","PeriodicalId":115975,"journal":{"name":"2017 29th International Conference on Microelectronics (ICM)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 29th International Conference on Microelectronics (ICM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICM.2017.8268879","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Comparators are essential blocks in implementing analog-to-digital converters (ADCs). An energy-efficient ADC such as successive approximation register (SAR) ADC or dual-slope ADC requires at least one comparator, where the power consumption mainly depends on the comparator design. This paper investigates various implementation techniques of low-power comparators emphasizing on their design performance metrics, and trade-offs such as sampling frequency, resolution, and power consumption. The proposed comparative analysis covers a recently published low power comparators for bio-signals monitoring and proposes a basic optimization method for these comparators. These comparators are redesigned using UMC 130nm CMOS technology for a fair comparison to present a good reference for proper choosing of a low power comparator that serves low-power bio-medical applications.