An Experimental Study on Control of a Pneumatic 6-DoF Gough-Stewart Robot Using Backstepping-Sliding Mode and Geometry-Based Quasi-Forward Kinematic Method

Amir Salimi Lafmejani, Behzad Danaei, A. Kalhor, M. T. Masouleh
{"title":"An Experimental Study on Control of a Pneumatic 6-DoF Gough-Stewart Robot Using Backstepping-Sliding Mode and Geometry-Based Quasi-Forward Kinematic Method","authors":"Amir Salimi Lafmejani, Behzad Danaei, A. Kalhor, M. T. Masouleh","doi":"10.1109/ICROM.2017.8466136","DOIUrl":null,"url":null,"abstract":"In this paper, the trajectory tracking control problem is addressed for a pneumatically actuated 6- DoF Gough-Stewart parallel robot. At first, dynamic model of the pneumatic system of each link of the robot which comprises a pneumatic actuator and a proportional electrical control valve is extracted. Unknown parameters of the obtained dynamic model consisting friction force, viscous coefficient and the parameters of the valve are identified by employing an evolutionary algorithm. Then, position control of the robot's pneumatic actuator is investigated based on designing Backstepping-Sliding Mode controller according to the nonlinear dynamic model of the pneumatic system. Moreover, kinematic equations of the 6- DoF parallel robot are achieved and a novel method is proposed, the so-called Geometry-based Quasi-Forward Kinematic, which calculates position of the end-effector of the robot without using expensive position sensors. Accordingly, kinematically closed-loop control of the parallel robot, which is based on simultaneous joint space and task space control, is investigated for trajectory tracking using potentiometers, a rotation sensor and based on the computed position of the end-effector by the proposed method. Desired sinusoidal pure rotations and translations are tracked in which root mean square error of the pure translations and rotations are lower than 1.3 (cm) and 2.6 (deg), respectively. The experimental results reveal that trajectory tracking control of the pneumatic 6-DoF Gough-Stewart parallel robot performs properly based on the proposed control strategies and the novel method for calculating position of the end-effector.","PeriodicalId":166992,"journal":{"name":"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICROM.2017.8466136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In this paper, the trajectory tracking control problem is addressed for a pneumatically actuated 6- DoF Gough-Stewart parallel robot. At first, dynamic model of the pneumatic system of each link of the robot which comprises a pneumatic actuator and a proportional electrical control valve is extracted. Unknown parameters of the obtained dynamic model consisting friction force, viscous coefficient and the parameters of the valve are identified by employing an evolutionary algorithm. Then, position control of the robot's pneumatic actuator is investigated based on designing Backstepping-Sliding Mode controller according to the nonlinear dynamic model of the pneumatic system. Moreover, kinematic equations of the 6- DoF parallel robot are achieved and a novel method is proposed, the so-called Geometry-based Quasi-Forward Kinematic, which calculates position of the end-effector of the robot without using expensive position sensors. Accordingly, kinematically closed-loop control of the parallel robot, which is based on simultaneous joint space and task space control, is investigated for trajectory tracking using potentiometers, a rotation sensor and based on the computed position of the end-effector by the proposed method. Desired sinusoidal pure rotations and translations are tracked in which root mean square error of the pure translations and rotations are lower than 1.3 (cm) and 2.6 (deg), respectively. The experimental results reveal that trajectory tracking control of the pneumatic 6-DoF Gough-Stewart parallel robot performs properly based on the proposed control strategies and the novel method for calculating position of the end-effector.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于后步-滑模和基于几何的准正运动学方法的气动六自由度高架机器人控制实验研究
研究了气动驱动六自由度Gough-Stewart并联机器人的轨迹跟踪控制问题。首先,提取了机器人各环节气动系统的动力学模型,该系统由气动执行器和比例电动控制阀组成。利用进化算法对得到的动力学模型中摩擦力、粘滞系数和阀芯参数等未知参数进行辨识。然后,根据气动系统的非线性动力学模型,设计了步进-滑模控制器,研究了机器人气动执行器的位置控制。在此基础上,建立了六自由度并联机器人的运动学方程,并提出了一种新的方法——基于几何的准正运动学,该方法可以在不使用昂贵的位置传感器的情况下计算机器人末端执行器的位置。在此基础上,研究了基于关节空间和任务空间同步控制的并联机器人运动闭环控制,利用电位器、旋转传感器和基于末端执行器位置计算的轨迹跟踪。跟踪期望的正弦纯平移和平移,其中纯平移和纯旋转的均方根误差分别低于1.3 (cm)和2.6(度)。实验结果表明,基于所提出的控制策略和末端执行器位置计算方法,气动六自由度Gough-Stewart并联机器人的轨迹跟踪控制效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design and Realization of a totally Embedded smart Insole FARAT1: an Upper Body Exoskeleton Robot Updating LQR Control for Full Dynamic of a Quadrotor Explicit dynamic and MTJ Control of a 3-RRS Parallel Manipulator with mass Compensator A Stabilizing Model Predictive Control for Nonlinear Fractional Order Systems with Polytopic Model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1