{"title":"Comparison of power control method for B4 converter connected to unbalanced grid","authors":"P. Šimek, V. Valouch","doi":"10.1109/EPE51172.2020.9269187","DOIUrl":null,"url":null,"abstract":"The aim of the paper is to present a power control of a three-phase inverter with only four inverter legs (connections B4) connected to an unbalanced grid. The results obtained by the predictive power control with a finite set of control values, the results obtained using a modified direct power control strategy, and the results obtained using a generalized predictive control are compared and discussed.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of the paper is to present a power control of a three-phase inverter with only four inverter legs (connections B4) connected to an unbalanced grid. The results obtained by the predictive power control with a finite set of control values, the results obtained using a modified direct power control strategy, and the results obtained using a generalized predictive control are compared and discussed.