Comparison of bio-impedance changes and EMG activity during daily events

Chulgyu Song, Keo-Sik Kim, Y. An, Jeong-Hwan Seo
{"title":"Comparison of bio-impedance changes and EMG activity during daily events","authors":"Chulgyu Song, Keo-Sik Kim, Y. An, Jeong-Hwan Seo","doi":"10.1109/BIOCAS.2008.4696951","DOIUrl":null,"url":null,"abstract":"A conventional method for measuring abdominal pressure involves the use of a fluid-filled rectal catheter. However, this method has some drawbacks, so it is limited to ambulatory urodynamics monitoring study. In this study, we proposed a novel method for estimating abdominal pressure in non invasive manner by changes in bio-impedance and electromyographic (EMG) signals. As a preliminary, we compared the bio-impedance changes and EMG activity during daily events, such as cough, sneeze and lumbar movement, while the abdominal pressure increased. The correlation coefficients between changes in bio-impedance and EMG signals, according to increases in abdominal contractions, were 0.72, 0.96, 0.90, 0.84 and 0.78 for the weak, strong, stronger, vigorous and maximal contraction, respectively. Also, daily activities such as coughing, sneezing and conversation, were sensitively monitored by measuring the change in amplitude of the bio-impedance signals, whilst EMG signals could not be used to detect these activities; therefore, the bio-impedance method is a more useful means of non-invasively measuring the changes in the abdominal pressure for urodynamics monitoring.","PeriodicalId":415200,"journal":{"name":"2008 IEEE Biomedical Circuits and Systems Conference","volume":"2011 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2008.4696951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A conventional method for measuring abdominal pressure involves the use of a fluid-filled rectal catheter. However, this method has some drawbacks, so it is limited to ambulatory urodynamics monitoring study. In this study, we proposed a novel method for estimating abdominal pressure in non invasive manner by changes in bio-impedance and electromyographic (EMG) signals. As a preliminary, we compared the bio-impedance changes and EMG activity during daily events, such as cough, sneeze and lumbar movement, while the abdominal pressure increased. The correlation coefficients between changes in bio-impedance and EMG signals, according to increases in abdominal contractions, were 0.72, 0.96, 0.90, 0.84 and 0.78 for the weak, strong, stronger, vigorous and maximal contraction, respectively. Also, daily activities such as coughing, sneezing and conversation, were sensitively monitored by measuring the change in amplitude of the bio-impedance signals, whilst EMG signals could not be used to detect these activities; therefore, the bio-impedance method is a more useful means of non-invasively measuring the changes in the abdominal pressure for urodynamics monitoring.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
日常活动中生物阻抗变化和肌电活动的比较
测量腹部压力的传统方法包括使用充满液体的直肠导管。然而,该方法存在一些缺陷,因此仅限于动态尿动力学监测研究。在这项研究中,我们提出了一种新的方法,通过生物阻抗和肌电图(EMG)信号的变化,以无创的方式估计腹部压力。作为初步研究,我们比较了在日常活动中,如咳嗽、打喷嚏和腰部运动时,腹部压力增加时的生物阻抗变化和肌电图活动。生物阻抗变化与肌电信号的相关系数分别为0.72、0.96、0.90、0.84、0.78。此外,通过测量生物阻抗信号的振幅变化,可以灵敏地监测咳嗽、打喷嚏和谈话等日常活动,而肌电图信号不能用于检测这些活动;因此,生物阻抗法是一种更有用的无创测量尿动力学监测腹部压力变化的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A wireless neural interface for chronic recording Development of novel SAW devices in CMOS technology for biosensor applications An efficient wireless power link for high voltage retinal implant FPGA implementation of 4-channel ICA for on-line EEG signal separation Pressure detection and wireless interface for patient bed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1