DVR with sweep mode control to alleviate voltage sags on a distribution system for three phase fault

P. Poornima, N. Veerappan, R. Sathyanarayanan
{"title":"DVR with sweep mode control to alleviate voltage sags on a distribution system for three phase fault","authors":"P. Poornima, N. Veerappan, R. Sathyanarayanan","doi":"10.1109/ICETEEEM.2012.6494452","DOIUrl":null,"url":null,"abstract":"The point of common coupling voltage during sag condition resulting due to a fault occurring on the parallel feeder in a distribution system evidently shows good dynamic response of the DVR achieved through the sweep mode control. It can also be observed that usage of sweep mode control to DVR eliminates the additional sag detection and makes the DVR multifunctional, such as the same control can be used to compensate any variation in the supply voltage.","PeriodicalId":213443,"journal":{"name":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","volume":"165 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETEEEM.2012.6494452","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The point of common coupling voltage during sag condition resulting due to a fault occurring on the parallel feeder in a distribution system evidently shows good dynamic response of the DVR achieved through the sweep mode control. It can also be observed that usage of sweep mode control to DVR eliminates the additional sag detection and makes the DVR multifunctional, such as the same control can be used to compensate any variation in the supply voltage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带扫频控制的DVR可缓解配电系统三相故障时的电压跌落
在配电系统并联馈线发生故障时,共耦合电压点表明,通过扫描方式控制,DVR具有良好的动态响应。还可以观察到,对DVR使用扫描模式控制消除了额外的凹陷检测,并使DVR多功能,例如可以使用相同的控制来补偿电源电压的任何变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling and simulation of thirty bus system employing solid state circuit breaker A real time embedded novel finger-vein recognition system for authenticated on teller machine A high speed reconfigurable virus detection processor for embedded network security Maintenance — Free solar energy drip irrigation using battery-less RF powered wireless sensors over AD-HOC network Differential Evolution algorithm based Weighted Additive FGA approach for optimal power flow using muti-type FACTS devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1