{"title":"Perancangan Alat Pendeteksi Asap dan Suhu Ruangan Berbasis Internet Of Think di PT. APAC Inti Corpora","authors":"Indra Ava Dianta, Moh muthohir, Ilham Ramasyahdani, Fatkhul Amin","doi":"10.51903/elkom.v15i2.859","DOIUrl":null,"url":null,"abstract":"In this final project the author discusses the problem entitled \"Design of Smoke Detector and Room Temperature of SAP ERP Server at PT Apac Inti Corpora\". This design aims to support the improvement of the security system in the server room with smoke and temperature detectors and microcontroller-based automatic countermeasures. Against the background of problems with sensors and countermeasures systems in the server room and lack of insight into sensor installation. This tool uses a gas sensor MQ-2 as a smoke detector, a DHT-11 sensor as a temperature detector, Arduino as a microcontroller that controls I/O, buzzer and LED as an alarm, a fan as a temperature controller, and an LCD to display conditions in the room. The output of the MQ-2 and DHT-11 sensors will be processed in a programmed microcontroller so that it can display conditions on the LCD. This tool will turn on the alarm and fan if smoke and high temperature are detected at the specified conditions.","PeriodicalId":118486,"journal":{"name":"Elkom : Jurnal Elektronika dan Komputer","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elkom : Jurnal Elektronika dan Komputer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51903/elkom.v15i2.859","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this final project the author discusses the problem entitled "Design of Smoke Detector and Room Temperature of SAP ERP Server at PT Apac Inti Corpora". This design aims to support the improvement of the security system in the server room with smoke and temperature detectors and microcontroller-based automatic countermeasures. Against the background of problems with sensors and countermeasures systems in the server room and lack of insight into sensor installation. This tool uses a gas sensor MQ-2 as a smoke detector, a DHT-11 sensor as a temperature detector, Arduino as a microcontroller that controls I/O, buzzer and LED as an alarm, a fan as a temperature controller, and an LCD to display conditions in the room. The output of the MQ-2 and DHT-11 sensors will be processed in a programmed microcontroller so that it can display conditions on the LCD. This tool will turn on the alarm and fan if smoke and high temperature are detected at the specified conditions.
在这个最后的项目中,作者讨论了题为“PT Apac Inti Corpora SAP ERP服务器的烟雾探测器和室温的设计”的问题。本设计旨在通过烟感、温度探测器和基于单片机的自动对抗来支持服务器室安全系统的改进。针对服务器机房中传感器和对策系统存在的问题以及对传感器安装缺乏深入了解的背景。该工具使用气体传感器MQ-2作为烟雾探测器,DHT-11传感器作为温度探测器,Arduino作为控制I/O的微控制器,蜂鸣器和LED作为报警,风扇作为温度控制器,LCD显示房间内的情况。MQ-2和DHT-11传感器的输出将在一个可编程的微控制器中进行处理,以便它可以在LCD上显示条件。当检测到烟雾和高温时,该工具将打开报警器和风扇。