Choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations

S. V. Belavskaya, A. Kuzmin, L. I. Lisitsyna, L. G. Navrotsky, V. V. Pedder
{"title":"Choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations","authors":"S. V. Belavskaya, A. Kuzmin, L. I. Lisitsyna, L. G. Navrotsky, V. V. Pedder","doi":"10.1109/APEIE.2014.7040741","DOIUrl":null,"url":null,"abstract":"The research on the choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations has been made. The experimental setup has been designed. It is shown that the maximum change of the piezoplate voltage is at the resonance frequency for both cases: contact with air and contact with skin surface. The optimum scanning signal frequency for the considered radiator is 485 kHz.","PeriodicalId":202524,"journal":{"name":"2014 12th International Conference on Actual Problems of Electronics Instrument Engineering (APEIE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 12th International Conference on Actual Problems of Electronics Instrument Engineering (APEIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEIE.2014.7040741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The research on the choice of scanning signal working frequency for skin surface sponginess estimation using ultrasonic vibrations has been made. The experimental setup has been designed. It is shown that the maximum change of the piezoplate voltage is at the resonance frequency for both cases: contact with air and contact with skin surface. The optimum scanning signal frequency for the considered radiator is 485 kHz.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声振动测量皮肤表面海绵性时扫描信号工作频率的选择
对超声振动估计皮肤表面海绵性时扫描信号工作频率的选择进行了研究。设计了实验装置。结果表明,在与空气接触和与皮肤表面接触两种情况下,压电板电压的最大变化都发生在谐振频率处。所考虑的散热器的最佳扫描信号频率为485 kHz。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Frequency converters based on oscillistor Correlation analysis of interference in the electrical minerals prospecting system Development of standard and measuring devices to determine the parameters of petroleum products Experience of network neuro-rehabilitation project implementation in Russia Design of PI and PID controllers for multivariable systems based on time-scale separation technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1