Non-stationary autoregressive model for on-line detection of inter-area oscillations in power systems

D. N. Sidorov, D. Panasetsky, V. Šmídl
{"title":"Non-stationary autoregressive model for on-line detection of inter-area oscillations in power systems","authors":"D. N. Sidorov, D. Panasetsky, V. Šmídl","doi":"10.1109/ISGTEUROPE.2010.5638992","DOIUrl":null,"url":null,"abstract":"This paper addresses early on-line detection of inter-area electro-mechanical oscillations in power systems using dynamic data such as currents, voltages and angle differences measured across transmission lines in real time. The main objective is to give the transmission operator qualitative information regarding stability margins. In our approach, the observed signal is modeled with the non-stationary second order autoregressive model. Bayesian estimation of the system is based on the forgetting approach. The stability margins are obtained as posterior probabilities that the poles of the estimated system are unstable. The approach is demonstrated on real retrospective data recorded in a 500 kV power grid and voltage data obtained by numerical simulations.","PeriodicalId":267185,"journal":{"name":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2010.5638992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This paper addresses early on-line detection of inter-area electro-mechanical oscillations in power systems using dynamic data such as currents, voltages and angle differences measured across transmission lines in real time. The main objective is to give the transmission operator qualitative information regarding stability margins. In our approach, the observed signal is modeled with the non-stationary second order autoregressive model. Bayesian estimation of the system is based on the forgetting approach. The stability margins are obtained as posterior probabilities that the poles of the estimated system are unstable. The approach is demonstrated on real retrospective data recorded in a 500 kV power grid and voltage data obtained by numerical simulations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电力系统区域间振荡在线检测的非平稳自回归模型
本文利用实时测量的输电线路上的电流、电压和角度差等动态数据,解决了电力系统中区域间机电振荡的早期在线检测。主要目的是为输电运营商提供有关稳定裕度的定性信息。在我们的方法中,用非平稳二阶自回归模型对观测信号进行建模。系统的贝叶斯估计是基于遗忘方法。稳定性裕度作为估计系统极点不稳定的后验概率得到。通过500kv电网的实测数据和数值模拟得到的电压数据,对该方法进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IEEE DEIS and Smart Grid: How to fit in Benchmarking set for domestic smart grid management Smart distribution protection using current-only directional overcurrent relay Operating conditions forecasting for monitoring and control of electric power systems Active distribution network — Demonstration project ADINE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1