{"title":"The influence of data size in statistical analysis of power transformer frequency response","authors":"M. Yousof, Shirllyana Riang, M. Uyup","doi":"10.1109/PECON.2016.7951630","DOIUrl":null,"url":null,"abstract":"Frequency Response Analysis (FRA) has been acknowledge as the most reliable and sensitive diagnostic tool to assess mechanical condition of power transformer. During assessing the integrity of transformer, proper and correct comparing interpretation of FRA response is become crucial. This paper presents and evaluates the influence of data size in statistical analysis when comparing the results of transformer frequency response. Three different statistical indicators are presented: the correlation coefficient (CC), the absolute sum of logarithmic error (ASLE) and the comparative standard deviation (CSD). The performance of these three selected statistical indicators while the data size varies is evaluated on simulated response. The same analysis is then repeated on frequency responses which were measured from an actual power transformer to test the validity of the earlier finding. In addition, the method of relative factor that proposed by the Chinese Standard DL 911/2004 is also evaluated and presented in this paper. Overall, this study concluded that the data size of the response does affect the statistical indicators. Recommendation is made that a standard data size is to be established and included in future FRA standard.","PeriodicalId":259969,"journal":{"name":"2016 IEEE International Conference on Power and Energy (PECon)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2016.7951630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Frequency Response Analysis (FRA) has been acknowledge as the most reliable and sensitive diagnostic tool to assess mechanical condition of power transformer. During assessing the integrity of transformer, proper and correct comparing interpretation of FRA response is become crucial. This paper presents and evaluates the influence of data size in statistical analysis when comparing the results of transformer frequency response. Three different statistical indicators are presented: the correlation coefficient (CC), the absolute sum of logarithmic error (ASLE) and the comparative standard deviation (CSD). The performance of these three selected statistical indicators while the data size varies is evaluated on simulated response. The same analysis is then repeated on frequency responses which were measured from an actual power transformer to test the validity of the earlier finding. In addition, the method of relative factor that proposed by the Chinese Standard DL 911/2004 is also evaluated and presented in this paper. Overall, this study concluded that the data size of the response does affect the statistical indicators. Recommendation is made that a standard data size is to be established and included in future FRA standard.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
数据大小对电力变压器频率响应统计分析的影响
频率响应分析(FRA)已被公认为是评估电力变压器机械状态最可靠、最灵敏的诊断工具。在对变压器完整性进行评估时,正确、合理地对FRA响应进行比较解释是至关重要的。本文提出并评价了统计分析中数据大小对变压器频率响应结果的影响。提出了三个不同的统计指标:相关系数(CC)、对数误差绝对和(ASLE)和比较标准差(CSD)。在模拟响应上评估这三个选定的统计指标在数据大小变化时的性能。然后对从实际电力变压器测量的频率响应进行相同的分析,以测试先前发现的有效性。此外,本文还对中国标准DL 911/2004提出的相对因子法进行了评价和介绍。总体而言,本研究得出的结论是,响应的数据大小确实影响统计指标。建议建立一个标准数据量,并列入未来的联邦资源评估标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A carrier-based PWM with synchronous switching technique for a vienna rectifier Denoising technique for partial discharge signal : A comparison performance between artificial neural network, fast fourier transform and discrete wavelet transform Simulation analysis of an improved cascaded multilevel inverter topology A review on basic principle of lightning location in multi-station system and the ability of single-station measurement Microgeneration of electrical energy using piezoelectric from car movement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1