A new approach to improve pulmonary function in quadriplegic people using dual synchronized functional electrical stimulation

T. D. Costa, E. Losso, G. N. Nogueira-Neto, P. Nohama
{"title":"A new approach to improve pulmonary function in quadriplegic people using dual synchronized functional electrical stimulation","authors":"T. D. Costa, E. Losso, G. N. Nogueira-Neto, P. Nohama","doi":"10.1109/PAHCE.2015.7173318","DOIUrl":null,"url":null,"abstract":"The main cause of death in individuals with high thoracic paraplegia and quadriplegia is the complication of the respiratory system. Transcutaneous functional electrical stimulation (TFES) synchronized with spontaneous breathing is a possible technique for respiratory rehabilitation. In this paper, we introduce a new approach to synchronized TFES and the two main muscles of ventilation: diaphragmatic and abdominal. The system under development can automatically perform a double synchronization with TFES and ventilatory muscles. It uses strain gage sensors-based load cell coupled to an elastic belt that is positioned on the thoraco-abdominal region so as to acquire the respiratory signal, and a detection algorithm of inspiratory and expiratory events for synchronization of TFES. After testing in four healthy persons, it was concluded that the proposed sensing system can be employed in the acquisition of respiratory signals. The described algorithm can provide TFES synchronization with the patient in quasi-static situation.","PeriodicalId":269877,"journal":{"name":"2015 Pan American Health Care Exchanges (PAHCE)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Pan American Health Care Exchanges (PAHCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAHCE.2015.7173318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The main cause of death in individuals with high thoracic paraplegia and quadriplegia is the complication of the respiratory system. Transcutaneous functional electrical stimulation (TFES) synchronized with spontaneous breathing is a possible technique for respiratory rehabilitation. In this paper, we introduce a new approach to synchronized TFES and the two main muscles of ventilation: diaphragmatic and abdominal. The system under development can automatically perform a double synchronization with TFES and ventilatory muscles. It uses strain gage sensors-based load cell coupled to an elastic belt that is positioned on the thoraco-abdominal region so as to acquire the respiratory signal, and a detection algorithm of inspiratory and expiratory events for synchronization of TFES. After testing in four healthy persons, it was concluded that the proposed sensing system can be employed in the acquisition of respiratory signals. The described algorithm can provide TFES synchronization with the patient in quasi-static situation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双同步功能电刺激改善四肢瘫痪患者肺功能的新方法
高胸截瘫和四肢截瘫患者的主要死亡原因是呼吸系统并发症。同步自主呼吸的经皮功能电刺激(TFES)是一种可能的呼吸康复技术。在本文中,我们介绍了一种新的方法同步TFES和两个主要的通气肌肉:膈肌和腹部。正在开发的系统可以自动执行与TFES和通气肌肉的双重同步。它采用基于应变传感器的称重传感器与位于胸腹区域的弹性带耦合来获取呼吸信号,并采用吸气和呼气事件的检测算法来实现TFES的同步。通过对4名健康人的实验,表明该传感系统可用于呼吸信号的采集。该算法可以实现准静态状态下与患者的TFES同步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proposal for monitoring the health status of a diabetic patient by using impedance spectroscopy measurement Exploring the usefulness of surface electromyography to evaluate the effect of PEEP on respiratory muscle activity during spontaneous ventilation Force control and haptic interface applied to prototype of myoelectric prosthetic hand HMM-GMM model's size selection methodology for bioacoustics-based diagnostic classification Raman spectroscopy analysis of a flexible and electrically conductive material with applications as ECG electrode
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1