{"title":"Calculation of Bi-mesa Structures Suitable for Mounting","authors":"S. Goka, Y. Mase, H. Sekimoto, Y. Watanabe","doi":"10.1109/FREQ.2006.275379","DOIUrl":null,"url":null,"abstract":"We calculated an improved bimesa structure, ones that has two mesa steps and is suitable for mounting using a two-dimensional finite element method in the X-Y' region. The frequency differences between clamp and free X-edge conditions were estimated as an index of mounting influences. When the outer mesa height was lower than 20% of the thick area, the frequency differences were less than 10% of standard-type bimesa resonator values. These results indicate that our bi-mesa structure has good separation from the mounting influences","PeriodicalId":445945,"journal":{"name":"2006 IEEE International Frequency Control Symposium and Exposition","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Frequency Control Symposium and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2006.275379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
We calculated an improved bimesa structure, ones that has two mesa steps and is suitable for mounting using a two-dimensional finite element method in the X-Y' region. The frequency differences between clamp and free X-edge conditions were estimated as an index of mounting influences. When the outer mesa height was lower than 20% of the thick area, the frequency differences were less than 10% of standard-type bimesa resonator values. These results indicate that our bi-mesa structure has good separation from the mounting influences